Tamura/NEC SF metal casing 15A Temperature fuse

The working principle of the AUPO / Tamura / NEC SF thermal fuse is based on the thermal expansion and conductive properties of the material. When the temperature in the circuit rises to the rated trigger temperature of the fuse, the metal material of the fuse will expand due to heat. When this expansion reaches a certain degree, it will cause the resistance inside the fuse to rise sharply.

The working principle of the AUPO / Tamura / NEC SF thermal fuse is based on the thermal expansion and conductive properties of the material. When the temperature in the circuit rises to the rated trigger temperature of the fuse, the metal material of the fuse will expand due to heat. When this expansion reaches a certain degree, it will cause the resistance inside the fuse to rise sharply. The increase in resistance will cause the fuse to heat up rapidly, further accelerating the expansion of the metal material. When the expansion reaches a certain degree, the fuse will disconnect in the circuit, thereby protecting the circuit and equipment from damage due to overheating.

Under normal circumstances, when the current passes through the thermal fuse, the fuse will maintain a low resistance state and will not affect the circuit.

When overheating occurs in the circuit, the thermal fuse begins to work. Its metal material expands due to heat, causing the resistance inside the fuse to change.

As the resistance rises, the fuse temperature rises further, accelerating the expansion of the metal material.

When the metal material expands to a certain extent, the resistance inside the fuse will rise sharply, causing the current in the circuit to be cut off.

After the fuse is disconnected, a new fuse needs to be replaced to restore the normal operation of the circuit. This is because it is difficult for the metal material to return to its original state after expansion, so that the resistance always remains high.

2. Structural features
Thermal fuse is a temperature sensing circuit cutting device with the characteristic of one-time fusing, that is, it only acts once at the fusing temperature and cannot be used again. Common types of thermal fuses include organic thermal fuses and alloy thermal fuses.

Taking the organic thermal fuse as an example, its structural features mainly include components such as temperature sensing block, compression spring and star spring. When the temperature around the organic thermal fuse rises to its operating temperature, the temperature sensing block will melt, and the compression spring will relax to make room, so that the star spring is pushed away to contact the pin, thereby disconnecting the current path. In this way, the circuit will be permanently cut off.

Product Features of Thermal Fuse
SEFUSE temperature fuse installation precautions:
1. When using lead bending, it should be bent from a part more than 6 mm from the root; When bending, do not damage the roots and leads, and do not pull, press, or twist the leads forcibly.
2. When the thermal fuse is fixed by screws, riveting or binding posts, it should be able to prevent mechanical creep and poor contact.
3. The connecting parts should be able to work reliably within the working range of the electrical product without displacement due to vibration and shock.
4.  When welding the lead wire, the heating humidity should be limited to a minimum, and no high temperature should be applied to the thermal fuse; Do not forcibly pull, press, or twist the thermal fuses and leads; after soldering, cool down immediately for more than 30 seconds.
5. The thermal fuse can only be used under the conditions of the specified rated voltage, current and specified temperature. Pay particular attention to the maximum continuous temperature that the thermal fuse can withstand.
Note: Nominal current, lead length and temperature can be designed according to customer requirements.

LE series Thermal Fuse (15A)

Product Features

Using temperature fuse metal casing and sense temperature organic particles.
Belonging unrecoverable type thermal fuses. Temperature fuse melting off, even if the surrounding temperature falls, it will not be turned on.
No lead (Pb) and cadmium (Cd), and comply with RoHS.
REACH does not contain the specified 46 categories SVHC (SVHC).

Product Size

250V 15A Temperature fuse

250V 15A Temperature fuse

Cable length Dimensions (mm)
A B C D E
Standard LE 4.0±0.1 20±3 10.1±3 35±3 1.0±0.1
Long LE(L) 4.0±0.1 38±3 10.1±3 35±3 1.0±0.1

 

Model Rated temperature
Tf(℃)
Operating temperature
(℃)
Rated current
(A)
Rated voltage
(V)
maintaining the temperature
Th(℃)
Maximum temperature limit
Tm(℃)
LE070 73 71±2 15.0 AC250 50 150
LE073 77 74±2 15.0 AC250 50 150
LE080 84 80±2 15.0 AC250 50 150
LE090 94 91+3/-2 15.0 AC250 65 150
LE095 99 95±2 15.0 AC250 71 150
LE108 113 109±2 15.0 AC250 85 150
LE117 121 117±3 15.0 AC250 95 160
LE124 128 124±3 15.0 AC250 102 160
LE128 133 129+3/-2 15.0 AC250 105 160
LE138 142 138±3 15.0 AC250 110 160
LE152 157 152±2 15.0 AC250 130 175
LE169 172 167±2 15.0 AC250 145 190
LE189 192 189±3 15.0 AC250 165 300
LE213 216 213±2 15.0 AC250 190 300