Product Categories
Product Tags
armored thermocouples sensor
blade Fuse Holder
Car blade fuse
Car Fuse
Ceramic Tube Fuse
Circuit Breaker
Disc Thermostats
Ds18b20 Temperature Sensor
electrical Fuse
Fast/slow-blow fuse
Fuse box-holder
Glass Tube Fuse
Inline Fuse Holder
Limit Snap Disc Thermostat
Mini Circuit Breakers
Motor overload protector
Motor thermal protection
NTC sensor
NTC thermistor sensor
PCB Mount Fuse Holder
PPTC Resettable Fuse
PT100 Temperature sensor
PTC thermistor
sensor connector harness
Sensor Probes & Cables
single-stage capillary thermostat
Slow Blow Micro Fuse
Smart Thermostat
Surface Mount Fuses
Temp Cutoff Link
Temperature control switch
Temperature Fuse
Temperature Sensor
Temperature sensor cable
Temperature Sensor Probe
temp switch
Thermal cut-off
Thermal Cut out Switch
Thermal Fuse
thermal protector
Thermal switch
Thermistor Sensor Probe
Recent Posts
6.35×32 Ceramic Tube High Voltage Fuse 15a 250v Slow Blow
Determine the safety mark of 5×20, 3.6×10, 6.35×32 fuses: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.
Category: Electrical fuse
Tags: Ceramic Tube Fuse, electrical Fuse
a) Determine the safety mark of 5×20, 3.6×10, 6.35×32 fuses: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.
b) Determine the external dimensions: According to the installation space and the determined safety certification mark and safety standard, select the external dimensions of the fuse tube.
c) Determine the model: According to the current characteristics of the protected circuit, select the model of the fuse tube. For example, if the current characteristics of the protected circuit are constant current, select a fast-blow type.
d) Determine the rated voltage: According to the input voltage and usage requirements of the protected circuit, determine the rated voltage of the fuse tube. For example, if the input voltage of the protected circuit is 220V, a fuse tube with a rated voltage of more than 220V must be selected, and 250V, 300V, 350V, etc. can be selected. However, considering the cost factor, it is not necessary to select an excessively high rated voltage.
e) Determine the minimum rated current: According to the stable working current of the protected circuit and the relevant use loss coefficient, preliminarily determine the rated current of the fuse tube. For example, if the stable working current of the protected circuit is 1A, a UL standard time-delay fuse tube is selected, and the working environment temperature is about 80°C, then the minimum rated current of the fuse tube is: 1A×1.25÷0.5=2.5A.
f) Determine the minimum I2T of the fuse tube: Determine the I2T of the fuse tube according to the surge I2T of the protected circuit. For example, the surge I2T of the protected circuit is 1 (A2S). To ensure that the fuse tube can withstand more than 100,000 impacts, the I2T of the fuse tube should be greater than: 1÷0.2=5 (A2S).
g) Determine the rated current of the fuse tube: According to the minimum rated current and the minimum I2T value, check the corresponding model specifications in the product catalog. Take the primary rated current specification that is greater than the minimum rated current value and whose I2T value is also greater than the minimum I2T value as the rated current of the selected fuse tube. For example, based on the above minimum values.
(1) If the I2T of the rated current 2.5A is 4.3 A2S, and the I2T of 3A is 5.4A2S, then 3A is taken as the rated current of the selected fuse tube;
(2) If the I2T of the rated current 2A is 5.3 A2S, and the I2T of 2.5A is 7.6A2S, then 2.5A is taken as the rated current of the selected fuse tube.
Product Description
500V Ac 500Vdc 6.3×32 6×32 3AG Cartridge Fuse Fast Blow Ceramic Fuse Link 500V Tube Fuse For Replacement
Item | Ceramic Fuse |
Standard | UL |
Blow Type | fast acting |
Body Material | ceramic |
Fusing wire Material | Alloy |
Filler | silicon |
Cap Material | nickel plated brass |
Voltage Rating | 500 VAC 500 VDC |
Current Rating | 0.1A~30A |
Mounting Type | cartridge or axial leaded |
Breaking Capacity | 10KA 1KA |
Dimension | 6.35×31.75 mm 6.3×32 6×32 3AG |
Certificates | CUL UL |
Applications | home appliance, power supply, telecommunication, consuming electronics |
Product Features
Ambient Temperature: -55℃ ~ 125℃ (Consider de-rating)
Stored condition: at temperature of +10℃~60℃, relative humidity ≤ 75%.
Soldering pot temperature: <260℃; Solder dwell time: 2∼5s
Resistance to Soldering Heat: 260℃, 10s. (Wave); 350℃, 5s.
Solderability: 260℃, ≤ 3s. (Wave); 350±10℃, ≤ 3s.
Breaking Capacity UL certified
Amps | Volts | Interrupting Rating |
0.1A – 12A | 500V ac, 500V dc | 10KA |
0.1A – 30A | 500V ac, 500V dc | 1KA |
Specification
Amp
Code |
Rated
Current |
Rated
Voltage |
Approvals |
cURus | |||
0100 | 100mA |
500V AC |
● |
0200 | 200mA | ● | |
0250 | 250mA | ● | |
0315 | 315mA | ● | |
0400 | 400mA | ● | |
0500 | 500mA | ● | |
0630 | 630mA | ● | |
0800 | 800mA | ● | |
1100 | 1A | ● | |
1125 | 1.25A | ● | |
1150 | 1.5A | ● | |
1160 | 1.6A | ● | |
1200 | 2A | ● | |
1250 | 2.5A | ● | |
1300 | 3A | ● | |
1315 | 3.15A | ● | |
1400 | 4A | ● | |
1500 | 5A | ● | |
1630 | 6.3A | ● | |
1700 | 7A | ● | |
1800 | 8A | ● | |
2100 | 10A | ● | |
2125 | 12.5A | ● | |
2150 | 15A | ● | |
2160 | 16A | ● | |
2200 | 20A | ● | |
2250 | 25A | ● | |
2300 | 30A | ● |
Blow Time
Time vs Current Characteristics:UL248-1/14 | ||
Rated current | 100% | 200% |
Blowing Time | >4hs | <5s |
Standard Package
200pcs per bag, 2000pcs per box, 8000pcs per carton
Shipping Term:
EXW, DDU, DDP, C&F, FOB
Contact Us