Product Categories
Product Tags
armored thermocouples sensor
blade Fuse Holder
Car blade fuse
Car Fuse
Ceramic Tube Fuse
Circuit Breaker
Disc Thermostats
Ds18b20 Temperature Sensor
electrical Fuse
Fast/slow-blow fuse
Fuse box-holder
Glass Tube Fuse
Inline Fuse Holder
Limit Snap Disc Thermostat
Mini Circuit Breakers
Motor overload protector
Motor thermal protection
NTC sensor
NTC thermistor sensor
PCB Mount Fuse Holder
PPTC Resettable Fuse
PT100 Temperature sensor
PTC thermistor
sensor connector harness
Sensor Probes & Cables
single-stage capillary thermostat
Slow Blow Micro Fuse
Smart Thermostat
Surface Mount Fuses
Temp Cutoff Link
Temperature control switch
Temperature Fuse
Temperature Sensor
Temperature sensor cable
Temperature Sensor Probe
temp switch
Thermal cut-off
Thermal Cut out Switch
Thermal Fuse
thermal protector
Thermal switch
Thermistor Sensor Probe
Recent Posts
88A Manual Reset Protector KUOYUH MINI Overcurrent Protector Breaker
88A series equipment manual reset circuit breakers (commonly known as motor overcurrent protectors) are suitable for AC 50/60Hz, rated working voltage to 250Vac, DC 32Vdc, rated current to 3A-20A for additional overload protection in the internal branch circuit of electrical equipment, a key part of the product The temperature sensing protector.
88A series equipment manual reset circuit breakers (commonly known as motor overcurrent protectors) are suitable for AC 50/60Hz, rated working voltage to 250Vac, DC 32Vdc, rated current to 3A-20A for additional overload protection in the internal branch circuit of electrical equipment, a key part of the product The temperature sensing protector. 88 Series Push-to-Reset circuit breaker is a unipolar, single-push reset thermal protector product, used to protect motor equipment.
Product name: 88A series
rating :3A-20A;
(Input Power):125VAC/250VAC/32VDC 50-60Hz;
(Withstand voltage strength):1500VAC/1min;
Leakage current: ≤0.5mA(1500VAC/min,the leaked current is less than≤0.5mA);
(Insulation Resistance):500VDC1Min≥100MΩ;
(Rated short-circuit capacity):125VAC/1000A,250VAC/1000A;
(Rated breaking capacity): 6 times rated current;
(reset): Manual Push Reset;
(Reset Time): Within 60s”;
Tripping characteristics
(The test environment temperature):25℃±3℃;
(200% of Ratcd Currcnt): 5-30s” Seconds Trip;
(150% of Rated Current): Trip within 1 Hour;
(100% of Rated Current): Hold, No Trip ;
Main Technical Parameters
Rated Current | 125/250VAC |
32VDC | |
Rated Voltage | XXA |
Interrupt Capacity | 1000A(UL1077) |
Insulation Resistance | 500VDC 5s″, insulation resistance≥100ΜΩ |
Dielectric Strength | 1500VAC/min |
Reset Time | within 60S |
Reset Type | Manual reset |
Mechanical/Environmental Data
Working temperature: -10℃ to 60℃
Terminal: Quick-connect terminal or solder terminal
Nut: a variety of options, see product appendix and diagram
Terminal temperature rise: rated current <65℃ (ambient temperature is 25℃)
Contact life: >500Cycles at rated current and 125VAC×150%
Table of Environmental Correction Factors
(Derating Factor) | |
-5°C | (3A-4A)×1.2, (5A-30A)×1.12 |
+40°C | (3A-4A)×0.92,(5A-30A)×0.94 |
The time current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping. Please multiply the current brea ker current ratings by the derating factor shown below
Example:
Normal Continuous Current= 10A
Ambient Temperature = 45 °C
Multiplication Factor = 0.85
Recommended Rating=10A/0.85=11.8A
Select the Nea rest Rating = 12A
OVERLOAD | TRIP TIME |
150% | Trip in a hour |
200% | 5.0-30.0 SEC |
300% | 1.2-12.0 SEC |
400% | 0.6-5.0 SEC |
500% | 0.4-2.8 SEC |
600% | 0.3-1.8 SEC |
800% | 0.18-0.9 SEC |
1000% | 0.12-0.7 SEC |
Performance form of the experiment
Max Resistance V.S.Current Rating at 25℃ | Derating Factor | ||
Temperature | Rating Amp | ||
Current Rating in Amp | Max Resistance in ohms | 60℃ | X 0.6 |
3-4Amp | < 0.05 | 50℃ | X 0.7 |
5-6Amp | < 0.04 | 40℃ | X 0.8 |
7-8Amp | < 0.025 | 30℃ | X 0.9 |
9-11Amp | < 0.02 | 25℃ | X 1.0 |
12-13Amp | < 0.01 | 20℃ | X 1.1 |
14-16Amp | < 0.008 | 10℃ | X 1.3 |
17-25Amp | < 0.007 | 0℃ | X 1.5 |
Approval | File No. | Rated Current | Rated Voltage | Standard |
CUL | E155159 | 3-30A | 125/250VAC | UL1077 |
TUV | B140558611005 | 3-30A | 125-250VAC | EN60934 |
32VDC | ||||
CCC | 2011010307520568 | 3-30A | 125/250VAC | GB17001 |
Contact Us
Waiting for your email, we will reply you within 12 hours with valuable information you needed.
RELATED PRODUCTS
17am thermal protector switch
17am thermal protector (KLIXON) working principle: 17am Motor Thermal Protector 17am019-031 60-160 Celsius Degree Normally Closed. The working principle of the TI 17AM thermal protector is based on bimetal technology. When the temperature or current increases, the heat generated is transferred to the bimetal strip.
klixon 3MP+PTC overload protector for motor power-off reset
3MP+PTC current overload protector (with power-off reset function)
PTC self-sustaining function: When the overload trips, it can be automatically turned on after cutting off the power supply.
With delay protection function. It is produced with the proprietary technology of Texas Instruments KLIXON ® in the United States.
Thermal Cut out Switch
The function of automatic cut-off switch to prevent overheating
The automatic cut-off device against overheating is an electronic technology protection device. It can automatically cut off the power supply when electrical equipment overheats to avoid damage and danger caused by overheating of electrical equipment. In modern electrical equipment, automatic cut-off devices to prevent overheating have become an indispensable safety measure.