فئات المنتجات
علامات المنتج
88A Manual Reset Protector KUOYUH MINI Overcurrent Protector Breaker
88A series equipment manual reset circuit breakers (commonly known as motor overcurrent protectors) are suitable for AC 50/60Hz, rated working voltage to 250Vac, DC 32Vdc, rated current to 3A-20A for additional overload protection in the internal branch circuit of electrical equipment, a key part of the product The temperature sensing protector.
88A series equipment manual reset circuit breakers (commonly known as motor overcurrent protectors) are suitable for AC 50/60Hz, rated working voltage to 250Vac, DC 32Vdc, rated current to 3A-20A for additional overload protection in the internal branch circuit of electrical equipment, a key part of the product The temperature sensing protector. 88 Series Push-to-Reset circuit breaker is a unipolar, single-push reset thermal protector product, used to protect motor equipment.
اسم المنتج: 88A series
rating :3A-20A;
(Input Power):125VAC/250VAC/32VDC 50-60Hz;
(Withstand voltage strength):1500VAC/1min;
تسرب الحالي: ≤0.5mA(1500VAC/min,the leaked current is less than≤0.5mA);
(مقاومة العزل):500VDC1Min≥100MΩ;
(Rated short-circuit capacity):125VAC/1000A,250VAC/1000A;
(Rated breaking capacity): 6 times rated current;
(reset): Manual Push Reset;
(Reset Time): Within 60s”;
Tripping characteristics
(The test environment temperature):25℃±3℃;
(200% of Ratcd Currcnt): 5-30ق” Seconds Trip;
(150% of Rated Current): Trip within 1 Hour;
(100% of Rated Current): Hold, No Trip ;
Main Technical Parameters
التصنيف الحالي | 125/250VAC |
32VDC | |
الجهد المقنن | XXA |
Interrupt Capacity | 1000أ(UL1077) |
مقاومة العزل | 500VDC 5s″, insulation resistance≥100ΜΩ |
القوة العازلة | 1500VAC/min |
Reset Time | within 60S |
Reset Type | Manual reset |
Mechanical/Environmental Data
درجة حرارة العمل: -10℃ to 60℃
صالة: Quick-connect terminal or solder terminal
Nut: a variety of options, see product appendix and diagram
Terminal temperature rise: rated current <65℃ (ambient temperature is 25℃)
Contact life: >500Cycles at rated current and 125VAC×150%
Table of Environmental Correction Factors
(Derating Factor) | |
-5درجة مئوية | (3A-4A)×1.2, (5أ-30 أ)×1.12 |
+40درجة مئوية | (3A-4A)×0.92,(5أ-30 أ)×0.94 |
The time current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping. Please multiply the current brea ker current ratings by the derating factor shown below
Example:
Normal Continuous Current= 10A
Ambient Temperature = 45 درجة مئوية
Multiplication Factor = 0.85
Recommended Rating=10A/0.85=11.8A
Select the Nea rest Rating = 12A
OVERLOAD | TRIP TIME |
150% | Trip in a hour |
200% | 5.0-30.0 SEC |
300% | 1.2-12.0 SEC |
400% | 0.6-5.0 SEC |
500% | 0.4-2.8 SEC |
600% | 0.3-1.8 SEC |
800% | 0.18-0.9 SEC |
1000% | 0.12-0.7 SEC |
Performance form of the experiment
Max Resistance V.S.Current Rating at 25℃ | Derating Factor | ||
درجة حرارة | Rating Amp | ||
Current Rating in Amp | Max Resistance in ohms | 60℃ | X 0.6 |
3-4أمبير | < 0.05 | 50℃ | X 0.7 |
5-6أمبير | < 0.04 | 40℃ | X 0.8 |
7-8أمبير | < 0.025 | 30℃ | X 0.9 |
9-11أمبير | < 0.02 | 25℃ | X 1.0 |
12-13أمبير | < 0.01 | 20℃ | X 1.1 |
14-16أمبير | < 0.008 | 10℃ | X 1.3 |
17-25أمبير | < 0.007 | 0℃ | X 1.5 |
موافقة | File No. | التصنيف الحالي | الجهد المقنن | معيار |
كول | E155159 | 3-30أ | 125/250VAC | UL1077 |
توفالو | B140558611005 | 3-30أ | 125-250VAC | EN60934 |
32VDC | ||||
سي سي سي | 2011010307520568 | 3-30أ | 125/250VAC | GB17001 |
اتصل بنا
في انتظار البريد الإلكتروني الخاص بك, سوف نقوم بالرد عليك في غضون 12 ساعات مع المعلومات القيمة التي تحتاجها.