China custom bimetallic thermal disc cutoff switch has surface mount and PCB plug-in installation. Overheat circuit cutoffs switch (Bimetall-Thermostat) sind Vorrichtungen, die dazu dienen, Komponenten in Situationen zu schützen, in denen eine übermäßige Temperatur auftritt. List of Select Surface Mount Thermal Switches and thermal protectors product Specs, datasheets, manufacturers & suppliers.
Surface Mount Bimetal disc Thermal Switch are indispensable components in the safe and efficient operation of motors/ Electrical appliances. Durch Verhinderung von Überhitzung, they protect Electrical appliancesfrom damage, verlängern ihr Betriebsleben, Reduzieren Sie das Risiko von Brandgefahren, Sicherstellen Sie einen sicheren Betrieb, und minimieren Sie Ausfallzeit- und Wartungskosten. Außerdem, Bimetal disc thermal switch help in complying with industry safety standards, Betreiber und Stakeholder beruhigen. Als technologische Fortschritte, thermal switch continue to evolve, präziseren und zuverlässigeren Schutz für Motoren in einer Vielzahl von Anwendungen.
Mit der Entwicklung der Technologie, Der Anwendungsbereich des Motors ist immer umfangreicher, insbesondere der Einsatz von Motor im täglichen Leben und Produktion ist auch immer wichtiger. Aber auch der Motorverbrennungsunfall tritt auf, im wirklichen Leben, Der Motorverbrennen wird hauptsächlich durch die folgenden blockierten Spulenüberhitzung verursacht, Die Last ist zu groß, Mangel an Phase und anderen Gründen. Installing a heat protector is one of the effective ways to protect the motor. Thermischer schalter, Auch als Temperaturschalter bezeichnet, Temperaturkontrollschalter, usw. Es handelt sich um eine Art Temperaturschalter mit Bimetalblatt als Temperatursenselement, Wenn das elektrische Gerät normal funktioniert, Das Bimetalblatt befindet sich in einem freien Zustand, Der Kontakt befindet sich in einem nicht verbundenen Zustand, Wenn die Temperatur zum Aktionstemperaturwert steigt, Das bimetale Element wird erhitzt, um interne Stress und schnelle Wirkung zu erzeugen, Öffnen Sie den Kontakt, Schneiden Sie die Schaltung ab/anschließen/anschließen, so as to play a bimetal thermal switch role. Wait until the ambient temperature drops to thereset temperature of the protector, Der Kontakt enthält die angeschlossene Schaltung erneut, Und der Motor wird wieder funktionieren.
Choosing The Right thermal switch
How to choose the right circuit Off bimetal disc switch is very important, Andernfalls kann nicht nur keine Schutzrolle spielen, wird jedoch dazu führen, dass der Motor aufgrund der falschen Auswahl nicht funktionieren kann, oder sogar brennen.
1. Stromspannung & Strombestimmung
• Bimetal disc thermal switch have different voltage ranges 400V 380V 230V 220V 110V, DC motors will also have 36V 24V 12V, usw., according to different working voltages to choose different rated voltage protectors, grundsätzlich, Die tatsächliche Anwendungsspannung ist weniger oder gleich der Nennspannung des Beschützers, Zum Beispiel, 380V motor cannot choose rated voltage 220V protector, und Nennspannung 220 V Protektor kann im 110 -V -Motor verwendet werden;
• The current of the electrical appliances motors is divided into three kinds of starting current, Normaler Arbeitsstrom und blockierter Strom, the rated current of the protector should be greater than the maximum value of the three currents, und müssen einen Vorsprung hinterlassen. Zum Beispiel, Ein motorischer Normalarbeitstrom 1A, Stromstart 1,5A, Blockieren von Strom 2a, then the rated current of the selected protector is at least 2A, Und es ist am besten, den Nennstrom von 3a oder 5a zu wählen, um den Rand beizubehalten. Some motor starting current is greater than the rated current of the protector, Aber die Startzeit ist kürzer, und der normale Arbeitsstrom und der Blockierungsstrom sind geringer als der Nennstrom des Beschützers, in diesem Fall, Sie können auch diesen Beschützer auswählen. Weil der Startstrom größer ist als der Nennstrom, aber aufgrund der kurzen Zeit, the thermal effect of the current has not had time to make the double piece heat leading to protection of the protector, um nicht zu Unrecht zu verursachen.
2. Choose to thermal switch the temperature
• The choice of thermal switch temperature is related to three factors: insulation level of enameled wire, installation position and protector type.
The thermal switch temperature is lower than the maximum allowable temperature, Zum Beispiel, the maximum temperature ofF class is 155℃, and the actual selection can be 145℃ or 150℃.
•The installation position is divided into built-in inside the coil and bundled outside the coil, because when the motor is blocked and forwarded heat, the overheating phenomenon spreads from inside and outside. If the protector is buried in the interior, the thermal switch temperature is slightly lower than the highest temperature of the enamelled wire; If it is tied outside the coil, consider the temperature difference between the inside and outside, and choose a lower temperature protector. Zum Beispiel, the insulation level is F class enameled wire, coil inside and outside the temperature difference of 20℃, then choose 155-20=135℃ or so of the protector;
Motor protector has protection functions such as overload, phase failure, imbalance, underload, grounding/leakage, and stall. It can form a motor control protection unit with electrical components such as contactors and motor starters. It has functions such as remote automatic control, on-site direct control, panel indication, signal alarm, and field bus communication.
3. Selection of the thermal switch life
Different motor lock-in test time different requirements for the life of the protector are not the same, such as normal household motor lock-in 18 Tage, the number of cycles of normal action reset will not exceed 100000 mal, the rated voltage current life of more than 100000 times can be selected protector; Some pump motors only do 3 days of blocking, grundsätzlich, the life requirement is hundreds of times.
4. Selection of the thermal switch for sealing performance
Motor coil in the thermal switch process will dip paint to enhance the insulation performance of the process, dip paint is divided into drop paint, immersion, vacuum into the paint and other processes, especially the vacuum into the paint pressure is large, insulating paint is easy to enter the inside of the protector, resulting in the failure of the protector. The ST01 series of An Electronics has a very high sealing, under the condition of -0.08Abgeordneter, the paint dipping rate can reach 3%; In the case of -0.03Abgeordneter, the paint rate can reach less than one in ten thousand.
Motor protector parameters
technische Parameter
Auxiliary power supply |
Technical indicators | |||
ARD2(L) | ARD2F | ARD3 | ||
Auxiliary power supply | Stromspannung | AC85V~265V/DC100V~350V | ||
Stromspannung | ≤7VA | ≤15VA | ||
Nennarbeitsspannung | AC380V/AC660V,50Hz/60Hz | |||
Rated operating current | 1A(0.1~9999) | |||
5A(0.1~9999) | ||||
1.6A(0.4A~1.6A) | ||||
6.3A(1.6A~6.3A) | ||||
25A(6.3A~25A) | ||||
100A(25A~100A) | ||||
250A(63A~250A) | ||||
800A(250A~800A) | ||||
Relay output contact capacity | AC250V/ 3A;DC30V/ 3A | AC250V/ 6A | ||
Switch input | 2-way | 9-way | ||
Environment | Arbeitstemperatur: -10°C~55°C | |||
Storage temperature: -20°C~65°C | ||||
Relative humidity: 5﹪~95﹪ without condensation | ||||
Altitude: ≤ 2000m | ||||
Pollution level | 2 | |||
Protection level | IP20 | Main unit IP20 Display unit IP45 | ||
Installation category | Level III |
Bimetal motor protector
technische Parameter | Technical indicators | ||
ARD3T auxiliary power supply | AC/DC 110 / 220V or AC 380V,power consumption≤15VA | ||
Motor rated working voltage | AC 380V / 660V,50Hz / 60Hz | ||
Motor rated working current | 1.6(0.40A-2.00A) | Measured using measurement module | |
6.3(1.6A-6.3A) | |||
25(6.3A-25A) | |||
100(25A-100A) | |||
250(63A-250A) | Using external current transformer + measurement module | ||
800(250A-800A) | |||
Leckstrom | 50mA-1A | Using measurement module + leakage current transformer | |
3A-30A | |||
Relay output contact capacity | Resistive load | AC250V、6A;DC24V、6A | |
Inductive load | AC250V、2A;DC24V、2A | ||
Main switch input and output | 4DI、4DO,DI Can be dry or wet node | ||
Switch module | 4DI、3DO,DI Can be dry or wet node | ||
Temperature module | External sensor type:PT100、PT1000、Cu50、PTC、NTC
Number of sensor channels: 3 Corresponding measurement range of sensor: PT100/PT1000:-50°C~+500°C Cu50:-50°C~+150°C PTC/NTC:100Ω~30kΩ |
||
Analog module | Can be realized: 2-way 4~20mA input measurement, 2-way 4~20mA transmission output
4~20mA input measurement accuracy ±0.5% 4~20mA output maximum load capacity is ≤500Ω |
||
Main communication | RS485:Modbus-RTU | ||
Communication module | RS485:Dual Modbus-RTU、Profibus | ||
Environment | Arbeitstemperatur | -10ºC~55ºC | |
Storage temperature | -25ºC~65ºC | ||
Relative humidity | ≤95﹪No condensation, kein korrosives Gas | ||
Altitude | ≤2000m | ||
Pollution level | Level 3 | ||
Protection level | Main body IP20, split display module IP45 (installed on the cabinet) | ||
Installation category | Level III | ||