10Un fusible de temperatura RY RH de 250 V para olla arrocera, Ventilador eléctrico

10A 250V RY RH thermal fuse before action:
The metal shell of the SF type overheat fuse contains a movable electrode, a spring and a thermistor. Spring B is installed in a compressed state, and the spring force is used to make lead A, movable electrode, metal shell and lead B conductive.

After the RY RH thermal fuse is activated:
When the ambient temperature exceeds the fuse action temperature, the heat transferred through the metal shell melts the thermistor particles, and springs A and B are both extended, but the elastic force in the A direction is large, forcing spring B to press toward the B side, thereby disconnecting lead A and the movable electrode to cut off the circuit.

2: Thermal circuit breaker (SM type)
The low melting point alloy is installed in the ceramic shell as a heat-sensitive material. Its cut-off current is 0.5A, 1A, and 2A. It has the advantage of being directly installed at the temperature detection location.

Fusible térmico Sanyuan serie RY fusible de temperatura 250V 10A

Fusible térmico Sanyuan serie RY fusible de temperatura 250V 10A

quality Alloy Type 250V 10A, 15A, 20A Square Thermal Fuses

quality Alloy Type 250V 10A, 15A, 20A Square Thermal Fuses

10A,20A,16A 250V RY RH Thermal Fuse Links

10A,20A,16A 250V RY RH Thermal Fuse Links

Principle:
Before action:
Lead A and lead B are connected to the circuit together with the fusible element. The outer surface of the rotator is covered with flux.
After operation:
The temperature of the fusible material rises with the rise of the ambient temperature, and it melts soon. Under the action of the flux and the surface tension of the fusible material, it instantly forms a ball, thereby cutting off the circuit.

4. Features and uses
1. Características:
a. Because of its small size, it is very sensitive to the ambient temperature.
b. Due to its airtight structure, the change caused by aging is very small, and it has a very high operating temperature.
c. It is a non-recovery type, and it will not recover even if the temperature drops after operation.
2. Uses:
I. Electric stoves, electric hot tables, electric carpets, kerosene fan heaters, warm air blowers.
I. Electric irons, trouser presses, hot hair dryers, hair dryers, rechargeable shavers.
III. Air conditioners, ventilating fans, lavadoras, etc..
V. Refrigerators, color TVs, fluorescent lamps, etc..
V. Electric rice cookers, grills, cafeteras, electric money cookers.

Common installation methods include:
Welding, splicing, and welding
(1) Installation position: more than 5 mm from the fuse body.
(2) Do not allow the welding heat to cause the temperature to exceed the fuse action temperature during welding.
Solutions:
a. Clamp the tool or fixture near the shell to dissipate heat;
b. Shorten the operation time;
c. Reduce the welding temperature;
d. Weld away from the fuse body.
(3) Do not increase the resistance during splicing or welding.
If the resistance of the connection part is too large, abnormal heating will cause the fuse to operate when the power is turned on. Especially in splicing situations, the resistance will increase due to thermal cycles or temperature.
(4) After installation, do not pull, prensa, or twist the lead wire.
(5) Do not allow the resin-sealed lead wire to contact the fuse body. If contact is made, the current can be transmitted to the other end through the metal shell, and the purpose of cutting off the circuit cannot be achieved.
(6) The SF type cannot contact the metal part of the installation part.
(7) When crimping, the rear part cannot be loose, and copper crimping terminals are suitable.
(8) The installation location should be where the machine is prone to failure and generates the most abnormal heat.

Item Name: Fusible térmico, Corte térmico, Thermal Link Part No.: DF/S
Clasificación de voltaje: 250V Clasificación actual: 16A 15A 10A
tf: 66~240 Degree Tipo de montaje: Axial Leaded
Blow Type: One Shot Operation Case Type: Metal
UL Listed: Yes RoHS Compliant: Yes
Halogen Free: Yes MPQ: 200pcs
MOQ: 2000pcs Standard Lead Length: 25.4+35milímetros
Long Lead Length: 35 +35milímetros Longitud del cuerpo: 10.5milímetros
High Light: 16A Thermal Cut Out Fuse, 240℃ Thermal Cut Out Fuse, VDE Fuse Link For Transformer

Descripción del Producto

DYE 250V 15A 16A Thermal Cutoff Fuse Thermal Cutout Link DF104S DF184S DF192S

Descripción del Producto

The Thermal DF Series Thermal Cutoffs are single action devices that open when

a preset temperature is reached. They do not reset. The active component of a thermal

cutoff is an electrically insulated thermal pellet. This pellet holds a spring loaded

contact against a fixed contact under normal operating temperatures. (See Fig. 1)

When the preset temperature of the cutoff is reached, the pellet liquifies, the springs

relax, and the spring loaded contact is moved away from the fixed contact, opening the

circuit. The DF Series is the right choice for applications requiring an inexpensive

limit protector with 15A capability.

Artículo fusible térmico, corte térmico, enlace térmico
Body Tyle Metal
Guíalo 1.3milímetros
Longitud del cable 25.4+35mm/35+35mm/Customized
Clasificación de voltaje 250V ac
Clasificación actual 16A 15A 10A
Tipo de montaje con terminales axiales
su cuerpo 4milímetros
Longitud del cuerpo 10.5milímetros
Certificaciones UL VDE

Product Features

Rated Current: UL 250V 10A/16A, VDE 15A, CCC 15A

Advantage: One shot operation, stable and precise, compact, durable and reliable by hermetic seal structure, excellently sensitive to ambient temperature.

Function: Fusible térmico, Widely Used in Electric Current Appliance as Heat Protection. When temperatures exceed the specified TF level, Electrical Contacts will Open.

Aplicaciones: Suitable for electric home appliances, electric industrial equipment, office automation equipment, plain paper copiers, transformadores, motores, etc..

Specification

(SEFUSE SF-E thermal fuse, corte térmico, enlace térmico)

Part

Number

tf(℃) Th tm(VDE) Rated

Actual

Rated

Voltaje

DF66S 66 42 110 15A

16A

10A

AC250V

AC125V

DF72S 72 50 115
DF77S 77 55 120
DF84S 84 60 125
DF91S 91 67 135
DF98S 98 76 140
DF100S 100 78 135
DF104S 104 80 150
DF110S 110 88 140
DF115S 115 95 170
DF119S 119 95 170
DF121S 121 95 170
DF128S 128 106 155
DF132S 132 110 155    
DF139S 139 117 170    
DF141S 141 117 171    
DF144S 144 120 250    
DF152S 152 128 176    
DF167S 167 142 210    
DF169S 169 145 300    
DF170S 170 146 300    
DF179S 179 155 300    
DF184S 184 160 300    
DF192S 192 162 290    
DF216S 216   2441    
DF222S 222 195 300    
DF228S 228 193 300    
DF240S 240 200 290    
DF260S 260 220 350    
DF280S 280 230 350    

 

Opening Temperature Tolerance: TF+0°C/-5°C

Clasificación de temperatura (tf):Temperatura nominal de apertura

Temperatura de mantenimiento (Th):Maximum temperature measured at the case end ofthe thermal cutoff at which the thermal cutoff can be maintained for a period for 168 horas sin abrir.

Temperatura máxima (tm):La temperatura máxima a la que se puede mantener un corte térmico durante 10 minutos como circuito abierto y luego se puede mantener al doble del voltaje nominal durante un período de 2 minutos durante los cuales sus propiedades mecánicas y eléctricas no se verán afectadas

Contáctenos

Esperando tu email, le responderemos dentro de 12 horas con la valiosa información que necesitabas.

PRODUCTOS RELACIONADOS

Solicitar presupuesto

Rellena nuestro formulario de solicitud de presupuesto y responderemos a tu mensaje lo antes posible!