6.35×32 Ceramic Tube High Voltage Fuse 15a 250v Slow Blow

Determine the safety mark of 5×20, 3.6×10, 6.35×32 sulakkeet: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.

a) Determine the safety mark of 5×20, 3.6×10, 6.35×32 sulakkeet: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.
b) Determine the external dimensions: According to the installation space and the determined safety certification mark and safety standard, select the external dimensions of the fuse tube.
c) Determine the model: According to the current characteristics of the protected circuit, select the model of the fuse tube. Esimerkiksi, if the current characteristics of the protected circuit are constant current, select a fast-blow type.
d) Determine the rated voltage: According to the input voltage and usage requirements of the protected circuit, determine the rated voltage of the fuse tube. Esimerkiksi, if the input voltage of the protected circuit is 220V, a fuse tube with a rated voltage of more than 220V must be selected, and 250V, 300V, 350V, jne. can be selected. kuitenkin, considering the cost factor, it is not necessary to select an excessively high rated voltage.
e) Determine the minimum rated current: According to the stable working current of the protected circuit and the relevant use loss coefficient, preliminarily determine the rated current of the fuse tube. Esimerkiksi, if the stable working current of the protected circuit is 1A, a UL standard time-delay fuse tube is selected, and the working environment temperature is about 80°C, then the minimum rated current of the fuse tube is: 1A×1.25÷0.5=2.5A.
f) Determine the minimum I2T of the fuse tube: Determine the I2T of the fuse tube according to the surge I2T of the protected circuit. Esimerkiksi, the surge I2T of the protected circuit is 1 (A2S). To ensure that the fuse tube can withstand more than 100,000 impacts, the I2T of the fuse tube should be greater than: 1÷0.2=5 (A2S).
g) Determine the rated current of the fuse tube: According to the minimum rated current and the minimum I2T value, check the corresponding model specifications in the product catalog. Take the primary rated current specification that is greater than the minimum rated current value and whose I2T value is also greater than the minimum I2T value as the rated current of the selected fuse tube. Esimerkiksi, based on the above minimum values.
(1) If the I2T of the rated current 2.5A is 4.3 A2S, and the I2T of 3A is 5.4A2S, then 3A is taken as the rated current of the selected fuse tube;
(2) If the I2T of the rated current 2A is 5.3 A2S, and the I2T of 2.5A is 7.6A2S, then 2.5A is taken as the rated current of the selected fuse tube.

6.35*32 High Voltage Ceramic Fuse 15a 250v Slow Break

6.35*32 High Voltage Ceramic Fuse 15a 250v Slow Break

6.35x32, 6x32 ceramic fuse tube 250mA, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 15A, 20A, 25A, 30A, 40A, 50A

6.35×32, 6×32 ceramic fuse tube 250mA, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 15A, 20A, 25A, 30A, 40A, 50A

6.35x32 SUPER FAST ACTING CERAMIC TUBE FUSES 1A TO 30A, MIN 500V

6.35×32 SUPER FAST ACTING CERAMIC TUBE FUSES 1A TO 30A, MIN 500V

Ceramic Fuse 6x30 6.35x32mm Fast Acting Time Lag 200mA 500mA 1A 2A 3A 4A 5A

Ceramic Fuse 6×30 6.35x32mm Fast Acting Time Lag 200mA 500mA 1A 2A 3A 4A 5A

Tuotteen kuvaus

500V Ac 500Vdc 6.3×32 6×32 3AG Cartridge Fuse Fast Blow Ceramic Fuse Link 500V Tube Fuse For Replacement

 

Tuote Keraaminen sulake
Vakio UL
Puhallustyyppi fast acting
Body Material keraaminen
Fusing wire Material Alloy
Filler silicon
Cap Material niklattua messinkiä
Jännitteen luokitus 500 VAC 500 VDC
Nykyinen luokitus 0.1A~30A
Asennustyyppi cartridge or axial leaded
Katkaisukapasiteetti 10KA 1KA
Ulottuvuus 6.35×31.75 mm 6.3×32 6×32 3AG
Certificates CUL UL
Sovellukset home appliance, power supply, telecommunication, consuming electronics

 

Tuotteen ominaisuudet

Ambient Temperature: -55℃ ~ 125℃ (Consider de-rating)

Stored condition: at temperature of +10℃~60℃, relative humidity ≤ 75%.

Soldering pot temperature: <260℃; Solder dwell time: 2∼5s

Resistance to Soldering Heat: 260℃, 10s. (Wave); 350℃, 5s.

Solderability: 260℃, ≤ 3s. (Wave); 350±10℃, ≤ 3s.

 

Breaking Capacity UL certified

Amps Volts Interrupting Rating
0.1A – 12A 500V ja, 500V dc 10KA
0.1A – 30A 500V ja, 500V dc 1KA

 

Erittely

Amp

Code

Arvioitu

Nykyinen

Arvioitu

Jännite

Hyväksynnät
cURus
0100 100mA

500V AC
500V AC

0200 200mA
0250 250mA
0315 315mA
0400 400mA
0500 500mA
0630 630mA
0800 800mA
1100 1A
1125 1.25A
1150 1.5A
1160 1.6A
1200 2A
1250 2.5A
1300 3A
1315 3.15A
1400 4A
1500 5A
1630 6.3A
1700 7A
1800 8A
2100 10A
2125 12.5A
2150 15A
2160 16A
2200 20A
2250 25A
2300 30A

 

Puhallusaika

Time vs Current Characteristics:UL248-1/14
Nimellisvirta 100% 200%
Blowing Time >4hs <5s

 

Vakiopaketti

200kpl per pussi, 2000pcs per box, 8000pcs per carton

Toimitusaika:

EXW, DDU, DDP, C&F, FOB

 

Ota yhteyttä

Sähköpostiasi odotellessa, vastaamme sinulle sisällä 12 tuntia arvokasta tietoa, jota tarvitset.

LIITTYVÄT TUOTTEET

Pyydä tarjous

Täytä tarjouspyyntölomakkeemme, niin vastaamme viestiisi mahdollisimman pian!