6.35×32 Ceramic Tube High Voltage Fuse 15a 250v Slow Blow

Determine the safety mark of 5×20, 3.6×10, 6.35×32 fusibles: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.

un) Determine the safety mark of 5×20, 3.6×10, 6.35×32 fusibles: According to the market requirements where the product will be sold, select the safety certification mark and safety standard (UL standard or IEC standard fuse) of the glass ~ ceramic fuse tube.
b) Determine the external dimensions: According to the installation space and the determined safety certification mark and safety standard, select the external dimensions of the fuse tube.
c) Determine the model: According to the current characteristics of the protected circuit, select the model of the fuse tube. Par exemple, if the current characteristics of the protected circuit are constant current, select a fast-blow type.
d) Determine the rated voltage: According to the input voltage and usage requirements of the protected circuit, determine the rated voltage of the fuse tube. Par exemple, if the input voltage of the protected circuit is 220V, a fuse tube with a rated voltage of more than 220V must be selected, and 250V, 300V, 350V, etc.. can be selected. Cependant, considering the cost factor, it is not necessary to select an excessively high rated voltage.
e) Determine the minimum rated current: According to the stable working current of the protected circuit and the relevant use loss coefficient, preliminarily determine the rated current of the fuse tube. Par exemple, if the stable working current of the protected circuit is 1A, a UL standard time-delay fuse tube is selected, and the working environment temperature is about 80°C, then the minimum rated current of the fuse tube is: 1A×1.25÷0.5=2.5A.
f) Determine the minimum I2T of the fuse tube: Determine the I2T of the fuse tube according to the surge I2T of the protected circuit. Par exemple, the surge I2T of the protected circuit is 1 (A2S). To ensure that the fuse tube can withstand more than 100,000 impacts, the I2T of the fuse tube should be greater than: 1÷0.2=5 (A2S).
g) Determine the rated current of the fuse tube: According to the minimum rated current and the minimum I2T value, check the corresponding model specifications in the product catalog. Take the primary rated current specification that is greater than the minimum rated current value and whose I2T value is also greater than the minimum I2T value as the rated current of the selected fuse tube. Par exemple, based on the above minimum values.
(1) If the I2T of the rated current 2.5A is 4.3 A2S, and the I2T of 3A is 5.4A2S, then 3A is taken as the rated current of the selected fuse tube;
(2) If the I2T of the rated current 2A is 5.3 A2S, and the I2T of 2.5A is 7.6A2S, then 2.5A is taken as the rated current of the selected fuse tube.

6.35*32 Fusible en céramique haute tension 15a 250v à coupure lente

6.35*32 Fusible en céramique haute tension 15a 250v à coupure lente

6.35x32, 6x32 ceramic fuse tube 250mA, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 15A, 20A, 25A, 30A, 40A, 50UN

6.35×32, 6×32 ceramic fuse tube 250mA, 1UN, 2UN, 3UN, 4UN, 5UN, 6UN, 8UN, 10UN, 15UN, 20UN, 25UN, 30UN, 40UN, 50UN

6.35x32 SUPER FAST ACTING CERAMIC TUBE FUSES 1A TO 30A, MIN 500V

6.35×32 SUPER FAST ACTING CERAMIC TUBE FUSES 1A TO 30A, MIN 500V

Ceramic Fuse 6x30 6.35x32mm Fast Acting Time Lag 200mA 500mA 1A 2A 3A 4A 5A

Ceramic Fuse 6×30 6.35x32mm Fast Acting Time Lag 200mA 500mA 1A 2A 3A 4A 5A

Description du produit

500V Ac 500Vdc 6.3×32 6×32 3AG Cartridge Fuse Fast Blow Ceramic Fuse Link 500V Tube Fuse For Replacement

 

Article Ceramic Fuse
Standard UL
Blow Type fast acting
Body Material céramique
Fusing wire Material Alloy
Filler silicon
Cap Material laiton nickelé
Tension nominale 500 ACC 500 VDC
Note actuelle 0.1A~30A
Type de montage cartridge or axial leaded
Capacité de coupure 10KA 1KA
Dimension 6.35×31.75 mm 6.3×32 6×32 3AG
Certificates CUL UL
Applications home appliance, power supply, telecommunication, consuming electronics

 

Product Features

Ambient Temperature: -55℃ ~ 125℃ (Consider de-rating)

Stored condition: at temperature of +10℃~60℃, relative humidity ≤ 75%.

Soldering pot temperature: <260℃; Solder dwell time: 2∼5s

Resistance to Soldering Heat: 260℃, 10s. (Wave); 350℃, 5s.

Solderability: 260℃, ≤ 3s. (Wave); 350±10℃, ≤ 3s.

 

Breaking Capacity UL certified

Ampères Volts Interrupting Rating
0.1UN – 12UN 500V ac, 500V dc 10KA
0.1UN – 30UN 500V ac, 500V dc 1KA

 

Spécification

Amp

Code

Rated

Actuel

Rated

Tension

Approbations
cURus
0100 100mA

500V CA
500V CA

0200 200mA
0250 250mA
0315 315mA
0400 400mA
0500 500mA
0630 630mA
0800 800mA
1100 1UN
1125 1.25UN
1150 1.5UN
1160 1.6UN
1200 2UN
1250 2.5UN
1300 3UN
1315 3.15UN
1400 4UN
1500 5UN
1630 6.3UN
1700 7UN
1800 8UN
2100 10UN
2125 12.5UN
2150 15UN
2160 16UN
2200 20UN
2250 25UN
2300 30UN

 

Temps de coup

Time vs Current Characteristics:UL248-1/14
Rated current 100% 200%
Blowing Time >4hs <5s

 

Forfait standard

200pièces par sac, 2000pcs per box, 8000pcs per carton

Conditions d'expédition:

EXW, DDU, DDP, C&F, GOUSSET

 

Contactez-nous

En attente de votre email, nous vous répondrons dans les 12 heures avec des informations précieuses dont vous aviez besoin.

PRODUITS CONNEXES

Demander un devis

Remplissez notre formulaire de demande de devis et nous répondrons à votre message dans les plus brefs délais!