China custom bimetallic thermal disc cutoff switch has surface mount and PCB plug-in installation. Overheat circuit cutoffs switch (bimetal thermostat) sont des dispositifs conçus pour assurer la sécurité des composants dans des situations où une température excessive se produit. List of Select Surface Mount Thermal Switches and thermal protectors product Specs, datasheets, manufacturers & suppliers.
Surface Mount Bimetal disc Thermal Switch are indispensable components in the safe and efficient operation of motors/ Electrical appliances. En évitant la surchauffe, they protect Electrical appliancesfrom damage, prolonger leur durée de vie opérationnelle, réduire les risques d'incendie, assurer un fonctionnement sûr, et minimiser les temps d'arrêt et les coûts de maintenance. En outre, Bimetal disc thermal switch help in complying with industry safety standards, offrir une tranquillité d’esprit aux opérateurs et aux parties prenantes. À mesure que la technologie progresse, thermal switch continue to evolve, offrant une protection plus précise et plus fiable pour les moteurs dans une large gamme d'applications.
Avec le développement de la technologie, la gamme d'applications du moteur est de plus en plus étendue, en particulier, l'utilisation du moteur dans la vie quotidienne et dans la production est également de plus en plus importante. Mais l'accident de brûlure de moteur arrive aussi, dans la vraie vie, la brûlure du moteur est principalement causée par la surchauffe de la bobine bloquée suivante, la charge est une surcharge du moteur trop importante, manque de phase et autres raisons. Installing a heat protector is one of the effective ways to protect the motor. interrupteur thermique, également appelé interrupteur de température, interrupteur de contrôle de la température, etc.. C'est une sorte de commutateur de température avec une feuille bimétallique comme élément de détection de température, lorsque l'appareil électrique fonctionne normalement, le bilame est à l'état libre, le contact est dans un état déconnecté, lorsque la température atteint la valeur de température d'action, l'élément bimétallique est chauffé pour produire une contrainte interne et une action rapide, ouvrir le contact, couper/connecter le circuit, so as to play a bimetal thermal switch role. Wait until the ambient temperature drops to thereset temperature of the protector, le contact refermera le circuit connecté, et le moteur fonctionnera à nouveau.
Choosing The Right thermal switch
How to choose the right circuit Off bimetal disc switch is very important, sinon, non seulement il ne peut pas jouer un rôle protecteur, mais cela empêchera le moteur de fonctionner à cause d'une mauvaise sélection, ou même brûler.
1. Tension & Détermination actuelle
• Bimetal disc thermal switch have different voltage ranges 400V 380V 230V 220V 110V, DC motors will also have 36V 24V 12V, etc., according to different working voltages to choose different rated voltage protectors, en principe, la tension d'application réelle est inférieure ou égale à la tension nominale du protecteur, Par exemple, 380V motor cannot choose rated voltage 220V protector, et le protecteur de tension nominale 220 V peut être utilisé dans un moteur 110 V.;
• The current of the electrical appliances motors is divided into three kinds of starting current, courant de fonctionnement normal et courant bloqué, the rated current of the protector should be greater than the maximum value of the three currents, et il faut laisser une marge. Par exemple, un moteur courant de fonctionnement normal 1A, courant de démarrage 1,5A, courant de blocage 2A, then the rated current of the selected protector is at least 2A, et il est préférable de choisir le courant nominal de 3A ou 5A pour conserver la marge. Some motor starting current is greater than the rated current of the protector, mais le temps de départ est plus court, et le courant de fonctionnement normal et le courant de blocage sont inférieurs au courant nominal du protecteur, dans ce cas, vous pouvez également choisir ce protecteur. Parce que le courant de démarrage est supérieur au courant nominal, mais à cause du peu de temps, the thermal effect of the current has not had time to make the double piece heat leading to protection of the protector, pour ne pas provoquer de mésaventure.
2. Choose to thermal switch the temperature
• The choice of thermal switch temperature is related to three factors: insulation level of enameled wire, installation position and protector type.
The thermal switch temperature is lower than the maximum allowable temperature, Par exemple, the maximum temperature ofF class is 155℃, and the actual selection can be 145℃ or 150℃.
•The installation position is divided into built-in inside the coil and bundled outside the coil, because when the motor is blocked and forwarded heat, the overheating phenomenon spreads from inside and outside. If the protector is buried in the interior, the thermal switch temperature is slightly lower than the highest temperature of the enamelled wire; If it is tied outside the coil, consider the temperature difference between the inside and outside, and choose a lower temperature protector. Par exemple, the insulation level is F class enameled wire, coil inside and outside the temperature difference of 20℃, then choose 155-20=135℃ or so of the protector;
Motor protector has protection functions such as overload, phase failure, imbalance, underload, grounding/leakage, and stall. It can form a motor control protection unit with electrical components such as contactors and motor starters. It has functions such as remote automatic control, on-site direct control, panel indication, signal alarm, and field bus communication.
3. Selection of the thermal switch life
Different motor lock-in test time different requirements for the life of the protector are not the same, such as normal household motor lock-in 18 jours, the number of cycles of normal action reset will not exceed 100000 fois, the rated voltage current life of more than 100000 times can be selected protector; Some pump motors only do 3 days of blocking, en principe, the life requirement is hundreds of times.
4. Selection of the thermal switch for sealing performance
Motor coil in the thermal switch process will dip paint to enhance the insulation performance of the process, dip paint is divided into drop paint, immersion, vacuum into the paint and other processes, especially the vacuum into the paint pressure is large, insulating paint is easy to enter the inside of the protector, resulting in the failure of the protector. The ST01 series of An Electronics has a very high sealing, under the condition of -0.08Député, the paint dipping rate can reach 3%; In the case of -0.03Député, the paint rate can reach less than one in ten thousand.
Motor protector parameters
Paramètres techniques
Auxiliary power supply |
Technical indicators | |||
ARD2(L) | ARD2F | ARD3 | ||
Auxiliary power supply | Tension | AC85V~265V/DC100V~350V | ||
Tension | ≤7VA | ≤15VA | ||
Rated working voltage | AC380V/AC660V,50Hz/60Hz | |||
Rated operating current | 1A(0.1~9999) | |||
5A(0.1~9999) | ||||
1.6A(0.4A~1.6A) | ||||
6.3A(1.6A~6.3A) | ||||
25A(6.3A~25A) | ||||
100A(25A~100A) | ||||
250A(63A~250A) | ||||
800A(250A~800A) | ||||
Relay output contact capacity | AC250V/ 3A;DC30V/ 3A | AC250V/ 6A | ||
Switch input | 2-way | 9-way | ||
Environment | Working temperature: -10°C~55°C | |||
Storage temperature: -20°C~65°C | ||||
Relative humidity: 5﹪~95﹪ without condensation | ||||
Altitude: ≤ 2000m | ||||
Pollution level | 2 | |||
Protection level | IP20 | Main unit IP20 Display unit IP45 | ||
Installation category | Level III |
Bimetal motor protector
Paramètres techniques | Technical indicators | ||
ARD3T auxiliary power supply | CA/CC 110 / 220V or AC 380V,power consumption≤15VA | ||
Motor rated working voltage | AC 380V / 660V,50Hz / 60Hz | ||
Motor rated working current | 1.6(0.40A-2.00A) | Measured using measurement module | |
6.3(1.6A-6.3A) | |||
25(6.3A-25A) | |||
100(25A-100A) | |||
250(63A-250A) | Using external current transformer + measurement module | ||
800(250A-800A) | |||
Leakage current | 50mA-1A | Using measurement module + leakage current transformer | |
3A-30A | |||
Relay output contact capacity | Resistive load | AC250V、6UN;DC24V、6UN | |
Inductive load | AC250V、2UN;DC24V、2UN | ||
Main switch input and output | 4DI、4DO,DI Can be dry or wet node | ||
Switch module | 4DI、3DO,DI Can be dry or wet node | ||
Temperature module | External sensor type:PT100、PT1000、Cu50、CTP、CTN
Number of sensor channels: 3 Corresponding measurement range of sensor: PT100/PT1000:-50°C~+500°C Cu50:-50°C~+150°C PTC/NTC:100Ω~30kΩ |
||
Analog module | Can be realized: 2-way 4~20mA input measurement, 2-way 4~20mA transmission output
4~20mA input measurement accuracy ±0.5% 4~20mA output maximum load capacity is ≤500Ω |
||
Main communication | RS485:Modbus-RTU | ||
Communication module | RS485:Dual Modbus-RTU、Profibus | ||
Environment | Working temperature | -10ºC~55ºC | |
Storage temperature | -25ºC~65ºC | ||
Relative humidity | ≤95﹪No condensation, pas de gaz corrosif | ||
Altitude | ≤2000m | ||
Pollution level | Level 3 | ||
Protection level | Main body IP20, split display module IP45 (installed on the cabinet) | ||
Installation category | Level III | ||