Disc Self Hold Thermal CUT OUT & Resistor Combination

The KSD301 / KSD302 series self-hold thermal cut-outs have an internal heater to stop them from auto-resetting. This means they can be located remotely and reset by switching off the applied voltage. KSD series 1/2″ , 3/4”disc manual-reset thermal cutouts offer extra thermal protection where auto-resetting devices are not desirable.

KSD301 / KSD302 thermostat disc self hold thermal cut out is a safety device that prevents a heater from overheating or faulting:

How thermostat disc self hold thermal cut out works?
When the temperature reaches a predetermined level, the thermostat opens, and the contacts remain open. The only way to reset the device is to remove power from the circuit.

 ½” (13mm) self-hold bimetal disc thermostat

½” (13mm) self-hold bimetal disc thermostat

KSD302 Self Hold Thermal Cutout Switch

KSD302 Self Hold Thermal Cutout Switch

self-hold thermal protector thermal overload protector

self-hold thermal protector thermal overload protector

thermostat disc self hold thermal cut out Benefits:
A self hold thermal cut out offers extra safety compared to an automatic reset device, and it works similarly to a manual reset device without the need for a push button.
Types of self hold thermal cut outs
Some types of self hold thermal cut outs include:
KSD301 / KSD302: A combination of a thermostat and a resistor, where the resistor is located below the thermostat’s contact arm.
KSD301 / KSD302 EAW SO: Similar to an auto-reset type, but with an internal heating resistor that prevents the bimetal disc from auto-resetting.
KSD302-T: A 1/2” disc PTC thermal cut-out that features easy mounting, rapid heat transmission, high durability, e alta precisione.

FEATURES
Recognized UL component, tested to UL standard 873
Available with surface, air sensing, well or cavity type mountings
High switching current 25~60 AMP/240 volts
Reliable temperature performance over the life of the device
Ultimate safety device in critical applications
Also available for 115VAC, 24VAC/DC, 48VAC/DC, applicazioni
Various mounting configurations along with different terminations available

CODICE Temperatura aperta Ripristina temp CODICE Temperatura aperta Ripristina temp
45 45± 5 ° C. ≥33 ° C. 140 140± 5 ° C. 100± 15 ° C.
50 50± 5 ° C. ≥35 ° C. 145 145± 5 ° C. 100± 15 ° C.
55 55± 5 ° C. 42± 6 ° C. 150 150± 5 ° C. 105± 15 ° C.
60 60± 5 ° C. 45± 8 ° C. 155 155± 5 ° C. 110± 15 ° C.
65 65± 5 ° C. 48± 10 ° C. 160 160± 5 ° C. 115± 15 ° C.
70 70± 5 ° C. 50± 12 ° C. 165 165± 5 ° C. 120± 15 ° C.
75 75± 5 ° C. 53± 14 ° C. 170 170±3°C 155± 5 ° C.
80 80± 5 ° C. 55± 15 ° C. 175 175± 5 ° C. 130± 15 ° C.
85 85± 5 ° C. 60± 15 ° C. 180 180± 5 ° C. 135± 15 ° C.
90 90± 5 ° C. 65± 15 ° C. 185 185± 5 ° C. 140± 15 ° C.
95 95± 5 ° C. 70± 15 ° C. 190 190± 5 ° C. 145± 15 ° C.
100 100± 5 ° C. 70± 15 ° C. 195 195± 5 ° C. 150± 15 ° C.
105 105± 5 ° C. 75± 15 ° C. 200 200± 5 ° C. 155± 15 ° C.
110 110± 5 ° C. 75± 15 ° C. 205 205± 5 ° C. 160± 15 ° C.
115 115± 5 ° C. 80± 15 ° C. 210 210± 5 ° C. 165± 15 ° C.
120 120± 5 ° C. 85± 15 ° C. 215 215± 5 ° C. 170± 15 ° C.
125 125± 5 ° C. 85± 15 ° C. 220 220± 5 ° C. 175± 15 ° C.
130 130± 5 ° C. 90± 15 ° C. 225 225± 5 ° C. 180± 15 ° C.
135 135± 5 ° C. 95± 15 ° C. 230 230± 5 ° C. 185± 15 ° C.