Productcategorieën
- Thermische schakelaar 63
- Auto zekering 19
- Zekeringen vastschroeven 7
- thermische zekering 29
- opbouwzekeringen 12
- thermistor 11
- PCB-gemonteerde zekeringhouder 27
- Kabelboom 4
- Blade-zekeringhouders 17
- thermostaat 44
- Elektrische zekering 14
- Thermische stroomonderbreker 20
- Zekeringkast-houder 36
- Temperatuursensor 52
Producttags
gepantserde thermokoppelsensor
mes Zekeringhouder
Autobladzekering
Auto zekering
Keramische buiszekering
Stroomonderbreker
Schijfthermostaten
Ds18b20 temperatuursensor
elektrische zekering
Snelle/trage zekering
Zekeringkast-houder
Glazen buiszekering
Inline-zekeringhouder
Limiet-klikschijfthermostaat
Mini-stroomonderbrekers
Beveiliging tegen overbelasting van de motor
Thermische motorbeveiliging
NTC-sensor
NTC-thermistorsensor
PCB-gemonteerde zekeringhouder
PPTC-resetbare zekering
PT100 Temperatuursensor
PTC-thermistor
sensorconnectorkabelboom
Sensorsondes & Kabels
eentraps capillaire thermostaat
Langzame microzekering
Opbouwzekeringen
Link voor tijdelijke afsnijding
Schakelaar voor temperatuurregeling
Temperatuur zekering
Temperatuursensor
Kabel voor temperatuursensor
Sonde van de temperatuursensor
temperatuur schakelaar
Thermische uitschakeling
Thermische uitschakelschakelaar
Thermische zekering
thermische beschermer
Thermische schakelaar
Thermistorsensorsonde
recente berichten
HI-Temp Rugged Bulb & Adjustable Capillary Thermostats
Bulb and Capillary: Copper for units rated at 120°C (248°F) and lower; nickel-plated copper for units between 95°C (203°F) and 290°C (504°F); tin-plated steel for units between 150°C (302°F) and 370°C (698°F)
Bulb and capillary thermostats made in China can replace AR/EGO / Rainbow MACHSWON / LDEXIN Series adjustable thermostat switch. The capillary bulb thermostat is a device that uses the liquid flow characteristics of the capillary to control the temperature. Its basic principle is to use the change in the movement state of the liquid in the bulb capillary to control the connection and disconnection of the circuit.
The capillary thermostat consists of a capillary and a temperature-sensing bulb element. One end of the capillary is connected to the controlled temperature device, and the other end is connected to the power supply through an electrical contact. The temperature-sensing element sends different signals according to the high and low controlled temperatures to control the closing and disconnection of the electrical contacts.
When the controlled temperature reaches the predetermined temperature, the liquid in the capillary bulb begins to expand, and through the action of the capillary, the control contact is cut off, the circuit is interrupted, and the temperature rise is controlled. On the contrary, when the controlled temperature decreases, the liquid in the capillary shrinks, the circuit contacts are closed, and the circuit is connected, so that the device heats up. Op deze manier, within a certain range, the controlled temperature will always remain within the predetermined range.
model. : EGO ts-120sr 32-248f ;
part no. : p-ts00663 ;
temperature range. : 0°c ~ 120°c (32°f ~ 268°f) ;
accuracy: ± 3°c (±14.8°f) ;
differential: 3±1.5°c (5.4°f±2.5°f) ;
max. ambient temp. for body: 120°c (266°f) ;
max. temperature for bulb: 140°c (324°f)
electric rating: 20a/250vac ;
switch circuit: single pole double throw (spdt) ;
mounting bracket: m4 fixed bracket (28mm from center to center) ;
direction of terminal: straight net ;
weight: 93g ;
bulb dimension: stainless, Ø5*106mm (± 5mm) ;
capillary length: stainless, 1000mm ± 50mm;
type of knob: r type
knob bending radius for cap. tube: min. 5mm .
◀caution & notice▶
please keep these instructions in mind before installing a thermostat to your equipment and contact the supplier if you have any questions or doubts. use it within the allowed electric rating for your safety. handle the bulb and capillary with care to prevent damage. do not bend the capillary less than a 5mm radius. do not bend the terminals by force. a damaged bulb can cause failure to achieve the desired temperature. the thermostat body should be installed away from heat sources. higher ambient temperatures can affect its normal function. the sensing bulb should be installed in or close to the heat source. otherwise, it may exceed the allowed tolerance. terminal deformation is not allowed for safety reasons. refund or replacement is not accepted for voluntary repairs or modifications. use the supplied parts with the thermostat. Bulb and Capillary Design; Long-Lasting, Snap-Action Mechanism; Double-Pole, Single-Throw Contacts; 3 Different Bulb Styles Available.
These thermostats use sensitive bulbs that can be used in confined locations. Styles 4 En 5 bulbs are designed for inserting in drilled holes in platens and dies or for direct immersion.
Sensors for air and pipeline heating applications (style 9) can be coiled to inside radii as small as 13 mm (½inch).
SPECIFICATIONS
Temperature Range: -20 to 370°C (-4 to 698°F)
Operating Voltage:
Single-Phase: 120 to 480V
3-Phase: 120 to 277V
Enclosure: General purpose
Contacts: DPST, open on temperature rise; at positive off position, contacts cannot close
Differential: ±4% of scale
Bulb and Capillary: Copper for units rated at 120°C (248°F) and lower; nickel-plated copper for units between 95°C (203°F) and 290°C (504°F); tin-plated steel for units between 150°C (302°F) and 370°C (698°F)
Neem contact met ons op
Wachten op uw e-mail, wij zullen u binnen antwoorden 12 uur met waardevolle informatie die u nodig had.
GERELATEERDE PRODUCTEN
China Temp Control Disc 3/4″ Limit Snap Thermostat With High Current
These precision custom 3/4″ bimetal Limit Snap Disc Thermostats can be used in high current applications; carrying up to AC 110V/400V, 15A-60A amps-240 Volts, for over 100,000 cycli. A 3/4″ bimetal thermodisc at the heart of our thermostat is set to a precise temperature range within -5°~393°F (-20°-200°C). Product certification: TUV, CE, UL, CUL, CQC.
SPST Limit 36T 3/4″ Snap Disc Thermostat Manual reset Thermal Switch
China Custom High current and high power (AC 15A , 20A, 25A ,30A,35A ,40A,45A ,50A, 60A) SPST Limit 36T 3/4" Snap Disc Thermodisc Switch Manual reset N.C. / N.O. Fits Replaces Breckwell Big E, P20, P22, P23, P24, P2000 P2700, Ashley APC4000 and USSC 5040 Pellet Stoves, Replaces 80683 Thermodis Safety Snap Switch.
SPST Limit Switch AC 36T Snap Disc Thermostat KSD302, KSD304
China custom to replace Rheem 36T SPST Limit Switch Snap Disc Thermostat AC 110V/400V, 10A/16A/45A~60A - Auto Reset (Flanged Airstream) #47-25334-01, 47-25334-01 SPST N/C A/R Limit (145 Open 125 Dichtbij), 47-25334-01, Rheem Limit Switch - Normally Closed, Close at 125F, Open at 145F, Manual Reset, 120 / 230VAC - 47-25334-01 - 47-25334-01.