92 Series Manual Reset Overload Protector Battery Circuit Breaker 32VDC 0.5A~20A

KUOYUH 92 Series Overload Protector Circuit Breaker has automatic reset protector, manual reset protector, switch and other series. It has passed CQC, TUV, VDE, ul, CE, CB, SAA, KC and other certifications. It can be used for additional overload protection in branch circuits inside electrical equipment with AC 50/60Hz, rated working voltage up to 250Vac, DC 32Vdc, and rated current 0.5A to 300A.

KUOYUH 92 Series Overload Protector Circuit Breaker has automatic reset protector, manual reset protector, switch and other series. It has passed CQC, TUV, VDE, ul, CE, CB, SAA, KC and other certifications. It can be used for additional overload protection in branch circuits inside electrical equipment with AC 50/60Hz, rated working voltage up to 250Vac, DC 32Vdc, and rated current 0.5A to 300A. Its key temperature sensing element is made of bimetallic material. It is both a thermal sensor and an operating mechanism. The action is accurate and reliable, and is widely used in various electromechanical appliances. When the current is overloaded, the bimetallic strip undergoes thermal deformation and immediately interrupts the current to protect the circuit. It is suitable for household appliances, ships, RVs, UPS, electric anchors, battery chargers, starters, various motors, itp.

92 Series Push-To-Reset thermal Circuit Breaker Over Current Overload Switch

92 Series Push-To-Reset thermal Circuit Breaker Over Current Overload Switch

92 Series 1.5 A 32VDC Manual Reset Overload Protector Battery Circuit Breaker

92 Series 1.5 A 32VDC Manual Reset Overload Protector Battery Circuit Breaker

92 Series Circuit Breaker 32VDC Manual Reset Overload Protector Battery

92 Series Circuit Breaker 32VDC Manual Reset Overload Protector Battery

Current rating range 2~20A
Input voltage rating 125/250ODKURZACZ; 50VDC
Interrupting Capacity 125/250VAC x 1,000A(ul 1077)
Typical life 1,000 operations at 200% overload
Insulation co-ordination Rated impulse withstand voltage 2.5kV
Dielectric Strength > 1,500VAC/min.
Insulation Resistance >100MOHM (DC 500V)
Degree of protection Terminal area IP00, operating area IP40
  • Mechanical/Environmental Data
  • Operating Ambient Temperature: -10℃ ℃
  • Termination: 250”(6.35mm)quick connects or solder terminals
  • Mounting: Various options. See Ordering Information and drawings
  • Compliance with Rohs

The product accords with the requirement of ROHS( 2011/65/EU)

Contacts use Exempted item of RoHS Directive 2010/571/EU 8(a)

Typical applications

Tarnsforms, Motors, Battery chargers, Power supplies,appliances, extra low voltage systems, machinery.

Product Description

92 Series Manual Reset Overload Protector Installation dimensions

92 Series Manual Reset Overload Protector Installation dimensions

92 Series Manual Reset Overload Protector 0.25~16A Trip Time Curves

92 Series Manual Reset Overload Protector 0.25~16A Trip Time Curves