Custom slow-blow F1A/250V 3×10 glass fuse with lead

The role of the 3.6x10mm fuseWhen a circuit malfunctions or is abnormal, the current is constantly rising, and the increased current may damage some important components or valuable components in the circuit, or it may burn the circuit or even cause a fire. The 3.6x10mm fuse will cut off the current when the current abnormally rises to a certain height and a certain time, thereby protecting the safe operation of the circuit.

In electrical circuits, whether it is AC power supply and distribution circuits or weak current electronic circuits, fuses are common electrical protection components. When an electrical circuit fails, the fuse can always be blown in time to protect the circuit and electrical equipment.

How does a 3.6*10mm fuse perform fuse protection? What are the characteristics of a 3.6*10mm fuse? How to choose a suitable fuse for daily maintenance? This article will answer three questions in detail, hoping to provide you with reference and help when repairing electrical circuits.

Nazwa produktu: 3.6*10mm tubular glass fuse
Product size: 3.6*10mm
Tworzywo: szkło, nickel-plated copper
Rated current: 250mA~12A
Napięcie znamionowe: AC250V/125V
Complies with: ciężki
Standard: ul 248-14

3.6x10 mm, 4x11mm Ceramic fuse fast and slow blowing 250mA, 1A, 2A, 3A, 4A, 5A, 8A, 10A, 12A

3.6x10 mm, 4x11mm Ceramic fuse fast and slow blowing 250mA, 1A, 2A, 3A, 4A, 5A, 8A, 10A, 12A

T1A 250V T1000MA slow-blow 3.6x10 Axial Lead Glass Fuse

T1A 250V T1000MA slow-blow 3.6×10 Axial Lead Glass Fuse

Mini Fuse 3.6x10mm 0.14x0.39 Inch F2.5AL125V-250V Fast-Blow Glass Fuses

Mini Fuse 3.6x10mm 0.14×0.39 Inch F2.5AL125V-250V Fast-Blow Glass Fuses

Product details
Time-current characteristics: fast fuse (F)
Breaking capacity: 50A@250Vac, 50A@125Vac
Standard: ul 248-14
Orzecznictwo: ciężki
Tworzywo: shell-glass tube, metal cap-nickel-plated brass, lead cap-nickel-plated cap, tinned copper wire
Temperatura pracy: -55℃ ~ +125℃
Weldability: 260℃≤5 seconds (wave soldering); 350℃≤3 seconds (manual soldering)
Soldering temperature bearing capacity: 260℃, 10 towary drugiej jakości; 280℃, 5 towary drugiej jakości
Storage conditions: +10℃ ~ +60℃; annual average relative humidity ≤75%, relative humidity reaching 95% for no more than 30 days

Pojemność zerwania Tworzywo Temperatura pracy Warunki lutowania
VDE:35A lub 10ln, w zależności od tego, co jest większe(250mA-15A)
ul:50 amperes at 125V/250V/300V AC (200MA-6.3A)
Bodyfizyjne korpus - szklanka rurki
Zakończ –Nikiel plastowany mosiądz
Warkoczyk–miedziana z cyny na niklu platowana mosiężna czapka
-40℃~+125 ℃ Lut fali:260℃,≤5s
Lutowanie rąk: 360℃,≤1s
Replacement Fuse 3x10mm Axial Fast Glass Fuse With Lead

Replacement Fuse 3x10mm Axial Fast Glass Fuse With Lead

Charakterystyka funkcjonalna

Prąd testowy Czas dmuchania
Min Maks
150% 1 godzina
210% 1 S 120S
275% 400SM 10S
400% 150SM 3S
1000% 20SM 150SM


Approvals(○ Pending● Approvals)

Aktualna ocena Napięcie znamionowe Topienie normalne
I2t(A2Sec)
Zatwierdzenia
VDE CQC ul Pse Kc
200mama 125V/250 V. 0.21
250mama 125V/250 V. 0.27
300mama 125V/250 V. 0.29
315mama 125V/250 V. 0.30
350mama 125V/250 V. 0.32
400mama 125V/250 V. 0.48
500mama 125V/250 V. 0.45
600mama 125V/250 V. 0.48
630mama 125V/250 V. 0.50
750mama 125V/250 V. 0.51
800mama 125V/250 V. 1.6
1A 125V/250 V. 4.2
1.25A 125V/250 V. 4.5
1.5A 125V/250 V. 4.9
1.6A 125V/250 V. 7.2
2A 125V/250 V. 12
2.5A 125V/250 V. 13
3A 125V/250 V. 13
3.15A 125V/250 V. 28
3.5A 125V/250 V. 30
4A 125V/250 V. 50
5A 125V/250 V. 80
6A 125V/250 V. 82
6.3A 125V/250 V. 127
7A 125V/250 V. 108
8A 125V/250 V. 125
10A 125V/250 V. 180

 

Skontaktuj się z nami

Czekam na Twój e-mail, odpowiemy Ci w ciągu 12 godziny z cennymi informacjami, których potrzebujesz.

POWIĄZANE PRODUKTY

Poproś o wycenę

Wypełnij nasz formularz zapytania ofertowego, a my odpowiemy na Twoją wiadomość tak szybko, jak to możliwe!