Product Categories
Product Tags
armored thermocouples sensor
blade Fuse Holder
Car blade fuse
Car Fuse
Ceramic Tube Fuse
Circuit Breaker
Disc Thermostats
Ds18b20 Temperature Sensor
electrical Fuse
Fast/slow-blow fuse
Fuse box-holder
Glass Tube Fuse
Inline Fuse Holder
Limit Snap Disc Thermostat
Mini Circuit Breakers
Motor overload protector
Motor thermal protection
NTC sensor
NTC thermistor sensor
PCB Mount Fuse Holder
PPTC Resettable Fuse
PT100 Temperature sensor
PTC thermistor
sensor connector harness
Sensor Probes & Cables
single-stage capillary thermostat
Slow Blow Micro Fuse
Smart Thermostat
Surface Mount Fuses
Temp Cutoff Link
Temperature control switch
Temperature Fuse
Temperature Sensor
Temperature sensor cable
Temperature Sensor Probe
temp switch
Thermal cut-off
Thermal Cut out Switch
Thermal Fuse
thermal protector
Thermal switch
Thermistor Sensor Probe
Recent Posts
Tamura/NEC SF metal casing 15A Temperature fuse
The working principle of the AUPO / Tamura / NEC SF thermal fuse is based on the thermal expansion and conductive properties of the material. When the temperature in the circuit rises to the rated trigger temperature of the fuse, the metal material of the fuse will expand due to heat. When this expansion reaches a certain degree, it will cause the resistance inside the fuse to rise sharply.
Category: thermal fuse
Tags: Temperature Fuse, Thermal cut-off, Thermal Fuse, thermal protector
The working principle of the AUPO / Tamura / NEC SF thermal fuse is based on the thermal expansion and conductive properties of the material. When the temperature in the circuit rises to the rated trigger temperature of the fuse, the metal material of the fuse will expand due to heat. When this expansion reaches a certain degree, it will cause the resistance inside the fuse to rise sharply. The increase in resistance will cause the fuse to heat up rapidly, further accelerating the expansion of the metal material. When the expansion reaches a certain degree, the fuse will disconnect in the circuit, thereby protecting the circuit and equipment from damage due to overheating.
Under normal circumstances, when the current passes through the thermal fuse, the fuse will maintain a low resistance state and will not affect the circuit.
When overheating occurs in the circuit, the thermal fuse begins to work. Its metal material expands due to heat, causing the resistance inside the fuse to change.
As the resistance rises, the fuse temperature rises further, accelerating the expansion of the metal material.
When the metal material expands to a certain extent, the resistance inside the fuse will rise sharply, causing the current in the circuit to be cut off.
After the fuse is disconnected, a new fuse needs to be replaced to restore the normal operation of the circuit. This is because it is difficult for the metal material to return to its original state after expansion, so that the resistance always remains high.
2. Structural features
Thermal fuse is a temperature sensing circuit cutting device with the characteristic of one-time fusing, that is, it only acts once at the fusing temperature and cannot be used again. Common types of thermal fuses include organic thermal fuses and alloy thermal fuses.
Taking the organic thermal fuse as an example, its structural features mainly include components such as temperature sensing block, compression spring and star spring. When the temperature around the organic thermal fuse rises to its operating temperature, the temperature sensing block will melt, and the compression spring will relax to make room, so that the star spring is pushed away to contact the pin, thereby disconnecting the current path. In this way, the circuit will be permanently cut off.
Product Features of Thermal Fuse
SEFUSE temperature fuse installation precautions:
1. When using lead bending, it should be bent from a part more than 6 mm from the root; When bending, do not damage the roots and leads, and do not pull, press, or twist the leads forcibly.
2. When the thermal fuse is fixed by screws, riveting or binding posts, it should be able to prevent mechanical creep and poor contact.
3. The connecting parts should be able to work reliably within the working range of the electrical product without displacement due to vibration and shock.
4. When welding the lead wire, the heating humidity should be limited to a minimum, and no high temperature should be applied to the thermal fuse; Do not forcibly pull, press, or twist the thermal fuses and leads; after soldering, cool down immediately for more than 30 seconds.
5. The thermal fuse can only be used under the conditions of the specified rated voltage, current and specified temperature. Pay particular attention to the maximum continuous temperature that the thermal fuse can withstand.
Note: Nominal current, lead length and temperature can be designed according to customer requirements.
LE series Thermal Fuse (15A)
Product Features
Using temperature fuse metal casing and sense temperature organic particles.
Belonging unrecoverable type thermal fuses. Temperature fuse melting off, even if the surrounding temperature falls, it will not be turned on.
No lead (Pb) and cadmium (Cd), and comply with RoHS.
REACH does not contain the specified 46 categories SVHC (SVHC).
Product Size
Cable length | Dimensions (mm) | ||||
A | B | C | D | E | |
Standard LE | 4.0±0.1 | 20±3 | 10.1±3 | 35±3 | 1.0±0.1 |
Long LE(L) | 4.0±0.1 | 38±3 | 10.1±3 | 35±3 | 1.0±0.1 |
Model | Rated temperature Tf(℃) |
Operating temperature (℃) |
Rated current (A) |
Rated voltage (V) |
maintaining the temperature Th(℃) |
Maximum temperature limit Tm(℃) |
LE070 | 73 | 71±2 | 15.0 | AC250 | 50 | 150 |
LE073 | 77 | 74±2 | 15.0 | AC250 | 50 | 150 |
LE080 | 84 | 80±2 | 15.0 | AC250 | 50 | 150 |
LE090 | 94 | 91+3/-2 | 15.0 | AC250 | 65 | 150 |
LE095 | 99 | 95±2 | 15.0 | AC250 | 71 | 150 |
LE108 | 113 | 109±2 | 15.0 | AC250 | 85 | 150 |
LE117 | 121 | 117±3 | 15.0 | AC250 | 95 | 160 |
LE124 | 128 | 124±3 | 15.0 | AC250 | 102 | 160 |
LE128 | 133 | 129+3/-2 | 15.0 | AC250 | 105 | 160 |
LE138 | 142 | 138±3 | 15.0 | AC250 | 110 | 160 |
LE152 | 157 | 152±2 | 15.0 | AC250 | 130 | 175 |
LE169 | 172 | 167±2 | 15.0 | AC250 | 145 | 190 |
LE189 | 192 | 189±3 | 15.0 | AC250 | 165 | 300 |
LE213 | 216 | 213±2 | 15.0 | AC250 | 190 | 300 |
Contact Us
Waiting for your email, we will reply you within 12 hours with valuable information you needed.
RELATED PRODUCTS
Custom Assembled Thermal cut-off fuse Connector Harness Assembly
Thermal cut-off fuse connector cables are specially used in the wiring harnesses of irons, smart toilets, refrigerators, air conditioners, washing machines, heat guns, rice cookers, electric kettles, vacuum cleaners, etc. Without thermal fuse connector harnesses, there is no circuit protection function for home appliances.
Emerson G4 / G5 series microtemp 10A / 20A thermal fuse
Emerson Group production MICROTEMP® G4 G5 series thermal fuse, According to different product specifications, Rated load current, respectively, up to AC250V 10A, AC120V 15A and DC24V 5A. To provide reliable protection against overheating, In the same industry products, MICROTEMP® G4 G5 series thermal fuse has established its flagship status can not be shaken.