Product Categories
Product Tags
armored thermocouples sensor
blade Fuse Holder
Car blade fuse
Car Fuse
Ceramic Tube Fuse
Circuit Breaker
Disc Thermostats
Ds18b20 Temperature Sensor
electrical Fuse
Fast/slow-blow fuse
Fuse box-holder
Glass Tube Fuse
Inline Fuse Holder
Limit Snap Disc Thermostat
Mini Circuit Breakers
Motor overload protector
Motor thermal protection
NTC sensor
NTC thermistor sensor
PCB Mount Fuse Holder
PPTC Resettable Fuse
PT100 Temperature sensor
PTC thermistor
sensor connector harness
Sensor Probes & Cables
Slow Blow Micro Fuse
Surface Mount Fuses
Temp Cutoff Link
Temperature control switch
Temperature Fuse
Temperature Sensor
Temperature sensor cable
Temperature Sensor Probe
temp switch
Thermal cut-off
Thermal Cut out Switch
Thermal Fuse
thermal protector
Thermal switch
Thermistor Sensor Probe
Thermocouple temperature measurement classification
Thermocouple sensors (Armored thermal resistance, Flameproof platinum resistance, High temperature precious metal (platinum rhodium) thermocouple, Anti-corrosion thermal resistance, End face thermal resistance, Power station thermocouple sensors, Hot runner thermocouple) is a kind of temperature sensing element. thermocouple directly measures temperature. Two different components of a conductor material composed of a closed loop. Due to different materials, different electron densities produce electron diffusion, and an electric potential is generated after stable equilibrium. When there is a gradient temperature at both ends, a current will be generated in the loop, generating thermoelectromotive force. The greater the temperature difference, the greater the current. The temperature value can be known after measuring the thermoelectromotive force. A thermocouple sensors is actually an energy converter that converts heat energy into electrical energy.
The technical advantages of thermocouples sensors: the thermocouple has a wide temperature measurement range, and its performance is relatively stable. The measurement accuracy is high, the thermocouple is in direct contact with the measured object, and is not affected by the intermediate medium. The thermal response time is fast, and the thermocouple responds flexibly to temperature changes. The measuring range is large, and the thermocouple can measure the temperature continuously from -40~+1600℃. The thermocouple has reliable performance and good mechanical strength. Long service life and convenient installation.
The galvanic couple must be composed of two conductor (or semiconductor) materials with different properties but meet certain requirements to form a loop. There must be a temperature difference between the measuring terminal and the reference terminal of the thermocouple.
The conductors or semiconductors A and B of two different materials are welded together to form a closed loop. When there is a temperature difference between the two attachment points 1 and 2 of the conductors A and B, an electromotive force is generated between the two, so a current of a magnitude is formed in the loop. This phenomenon is called the thermoelectric effect. Thermocouple is the application of this effect to work.
The thermocouple is actually a kind of energy converter. It converts thermal energy into electrical energy, and uses the generated thermoelectric potential to measure temperature. For the thermoelectric potential of a thermocouple, the following issues should be paid attention to :
1. The thermoelectric potential of a thermocouple is the difference between the temperature functions of the two ends of the thermocouple, not the temperature difference between the cold and working ends of the thermocouple.
2. The size of the thermoelectric potential generated by the thermocouple. When the material of the thermocouple is uniform, it has nothing to do with the length and diameter of the thermocouple, but only with the composition of the thermocouple material and the temperature difference between the two ends.
3. After the material composition of the two thermocouple wires of the thermocouple is determined, the thermoelectric potential of the thermocouple is only related to the temperature difference of the thermocouple. If the temperature of the cold junction of the thermocouple remains constant, the thermoelectric potential of the thermocouple is only a single value function of the temperature of the working junction. Solder two conductors or semiconductors A and B of different materials to form a closed loop, as shown in the figure. When there is a temperature difference between the two attachment points 1 and 2 of the conductors A and B, an electromotive force is generated between the two, thus forming an order of magnitude current in the loop. Thermocouples use this effect to work.
Straight handle handheld surface thermocouple thermometer probe Armored fast high temperature slender probe thermocouple
Contact Us
Waiting for your email, we will reply you within 12 hours with valuable information you needed.
RELATED PRODUCTS
DALLAS Ds18b20 Temperature Sensor Probe
Ultra-small size, ultra-low hardware overhead, strong anti-interference ability, high precision, and strong additional functions make DS18B20 more popular. The advantages of DS18B20 are our best choice for learning microcontroller technology and developing temperature-related small products. Understanding the working principles and applications can broaden your ideas for microcontroller development.
Production of platinum temperature sensor
STT-M series temperature sensors Probe are packaged with magnetic bodies. For paramagnetic metal surfaces, it can be easily sucked to the surface for temperature measurement and can be easily installed and removed. It is suitable for the detection of the key point temperature of large equipment before leaving the factory, and other occasions where the temperature detection point needs to be replaced frequently, so as to improve the efficiency of temperature detection
RTD PT100 Temperature Sensor Probe with Cable
What is a Platinum thermal resistance sensor?
An RTD (Resistance Temperature Detector) is a Platinum thermal resistance whose resistance changes with changes in temperature. Its resistance increases as the sensor temperature increases. The relationship between resistance and temperature is well known and repeatable over time. RTD is a passive device. It does not produce output by itself. External electronics can be used to measure the sensor resistance by passing a small current through the sensor to produce a voltage. Typically 1 mA or less measurement current, maximum 5 mA, without risk of self-heating.