Kategorije izdelkov
- Termično stikalo 63
- Avtomobilska varovalka 19
- Pritrjene varovalke 7
- toplotna varovalka 29
- površinsko nameščene varovalke 12
- termistor 10
- Nosilec varovalk za PCB 27
- Kabelski snop 4
- Držala rezilnih varovalk 17
- termostat 44
- Električna varovalka 14
- Termični odklopnik 20
- Nosilec škatle z varovalkami 36
- Temperaturni senzor 51
Oznake izdelkov
oklepni senzor termočlenov
Nosilec rezilne varovalke
Avtomobilska varovalka
Avtomobilska varovalka
Keramična cevna varovalka
Odklopnik
Disk termostati
Ds18b20 temperaturni senzor
električna varovalka
Hitro/počasna varovalka
Nosilec škatle z varovalkami
Varovalka iz steklene cevi
Inline držalo za varovalke
Termostat Limit Snap Disc
Mini odklopniki
Zaščita pred preobremenitvijo motorja
Termična zaščita motorja
NTC senzor
NTC termistorski senzor
Nosilec varovalk za PCB
Ponastavljiva varovalka PPTC
PT100 Temperaturni senzor
PTC termistor
priključni snop senzorja
Senzorske sonde & Kabli
single-stage capillary thermostat
Počasna mikro varovalka
Varovalke za površinsko montažo
Temp. izklopna povezava
Stikalo za nadzor temperature
Temperaturna varovalka
Temperaturni senzor
Kabel senzorja temperature
Sonda senzorja temperature
temperaturno stikalo
Toplotni izklop
Termično izklopno stikalo
Termična varovalka
toplotna zaščita
Termično stikalo
Senzor termistorja
Custom 60~300 Amp Marine Circuit Breaker Panel Mount 285, 16-3P Series 7084
Kategorija: Termični odklopnik
Oznake: Odklopnik, Mini odklopniki, Zaščita pred preobremenitvijo motorja, Termična zaščita motorja
Custom 285, 16-3P Series 7084/ E96 Thermal circuit breakers provides medium duty Mechanical Style circuit protection for 25 to 150 Amp loads when switching and circuit protection are both required. Discover the latest in Panel Mount 285-Series Circuit Breakers 7080 for medium duty circuit and switching. Water & Ignition Protected.
Drop in replacement for 185, 16-3P Series Series Circuit Breakers
Visible reset lever shows open condition
Ignition protected – Safe for installation aboard gasoline powered boats
Meets SAE J1171 external ignition protection requirements
Weather Resistant
Combines switching and circuit breaker function into one unit*
“Trip Free” – cannot be held closed after trip
Replaces Blue Sea Systems 7000, 7005, E96
Ime predmeta: | 285, 16-3P Series 7084 Odklopnik | del št.: | 285, 16-3P Series 7084, E96 |
Dimension: | 74×48.2x40mm | No. Of Pole: | Single |
Vrsta namestitve: | Panel Mount | Interrupting Rating: | 5KA@32VDC, 3KA@48VDC |
House Material: | Phenolic 94V-0 | Protection Grade: | IP67 |
Nazivna napetost: | 48V | Current Ratin0.1A~20Ag: | 20A 30A 40A 50A 60A 70A 80A 100A 125A 150A 200A 250A 300A |
Skladno z RoHS: | ja | Brez halogenov: | ja |
MPQ: | 100pcs Per Bag | Operation Temp: | -32˚C To +82˚C |
Torque Rating: | 50 In-Ib (5.6Nm) Max | ||
Visoka svetloba: | 285, 16-3P Series 7084 125A Automotive Circuit Breakers , E96 Panel Mount Breakers |
Opis izdelka
Product Name | Waterproof On-Off Switch Ignition Protected Circuit Breaker |
Types | Single Pole Thermal Type Breakers |
Volt Rating | 48V dc |
Amp Rating | 20A 30A 40A 50A 60A 70A 80A 100A 125A 150A 200A 250A 300A |
Interrupting Rating | 5KA@32VDC, 3KA@48VDC |
Material telesa | Black UL-rated 94V0 thermoset plastic |
Protection Rating | IP67 |
Termination | 1/4-28 or 3 8 16 threaded studs |
Operating Temperature | –25°F (–32°C) to 180°F (82°C) |
Storage Temperature | –30°F (–34°C) to 300°F (149°C) |
Compliance | SAE J1625; ABYC E-11; CE; SAE J1171 (ignition protected) |
Features
Single Pole Thermal Type Breakers
Typically used in auxiliary and accessory circuits in truck, bus’, RVs and marine systems.
Others include battery chargers and DC audio systems, compartment and bilge area applications.
Operating Temperature Rating:-25°F(-32°C) to 180°F(82°℃)
Storage Temperature Rating: -30°F(-34°C) to 300°F (149°C)
Materials: Black UL-rated 94V0 thermoset plastic.
Thermoplastic elastomer stud insulators areprovided on covered units with F-style (surface-mount) bases
Marking:Standard marking includes amp ratings and part numbers.Custom markings also available.
Termination: 1/4-28 or 3/8-16 threaded studs
Torque Rating: 50 in-lbs (5.6N•m) max
Mounting Torque Rating: Panel or surface-mount options; 50 in-lbs (5.6N•m ) max.Threaded insertoption has a max torque of 25 in-lbs (2.8N•m).
lngress Protection Rating: lp67
Compliances: SAE J1625;ABYCE-11;CE;SAEJ1171 (ignition protected)
Reset type: Manual Reset – Switchable
Standard Package
1pcs per bag, 100pcs per carton
Shipping Term:
EXW, DDU, DDP, C&F, FOB
Shipping Methods:
International Express, By Air, By Sea
Kontaktirajte nas
Čakam na vašo e-pošto, vam bomo odgovorili v roku 12 ure z dragocenimi informacijami, ki jih potrebujete.
PORODNI IZDELKI
92 Series Manual Reset Overload Protector Battery Circuit Breaker 32VDC 0.5A~20A
KUOYUH 92 Series Overload Protector Circuit Breaker has automatic reset protector, manual reset protector, switch and other series. It has passed CQC, TUV, VDE, UL, CE, CB, SAA, KC and other certifications. It can be used for additional overload protection in branch circuits inside electrical equipment with AC 50/60Hz, rated working voltage up to 250Vac, DC 32Vdc, and rated current 0.5A to 300A.
Circuit Breaker Magnetic Hydraulic Delay UL, CE TUV 50 A, 1 Pole, 250 V, 10 kA
Circuit Breaker Magnetic Hydraulic Delay Designed to handle higher current and voltage applications and qualified, as per agency approval, for branch circuit protection or as a supplementary protector. Marine Circuit Breaker for Boat Trolling with Manual Reset,Water Proof,12V- 48V DC. A range of marine-grade electrical panel boxes, switches, circuit breaker boxes, shunts, and meters, allowing you to complete your boat's electrical system.
Termično izklopno stikalo
The function of automatic cut-off switch to prevent overheating
The automatic cut-off device against overheating is an electronic technology protection device. It can automatically cut off the power supply when electrical equipment overheats to avoid damage and danger caused by overheating of electrical equipment. In modern electrical equipment, automatic cut-off devices to prevent overheating have become an indispensable safety measure.