Kategorije izdelkov
- toplotna varovalka 32
- površinsko nameščene varovalke 12
- termistor 17
- Nosilec varovalk za PCB 27
- Kabelski snop 4
- Držala rezilnih varovalk 17
- termostat 46
- Električna varovalka 14
- Termični odklopnik 20
- Nosilec škatle z varovalkami 36
- Temperaturni senzor 58
- Termično stikalo 64
- Avtomobilska varovalka 19
- Pritrjene varovalke 7
Oznake izdelkov
oklepni senzor termočlenov
Nosilec rezilne varovalke
Avtomobilska varovalka
Avtomobilska varovalka
Keramična cevna varovalka
Odklopnik
Disk termostati
Ds18b20 temperaturni senzor
električna varovalka
Hitro/počasna varovalka
Nosilec škatle z varovalkami
Varovalka iz steklene cevi
Inline držalo za varovalke
Termostat Limit Snap Disc
Mini odklopniki
Zaščita pred preobremenitvijo motorja
Termična zaščita motorja
NTC senzor
NTC termistorski senzor
Nosilec varovalk za PCB
Ponastavljiva varovalka PPTC
PT100 Temperaturni senzor
PTC termistor
priključni snop senzorja
Senzorske sonde & Kabli
enostopenjski kapilarni termostat
Počasna mikro varovalka
Pametni termostat
Varovalke za površinsko montažo
Temp. izklopna povezava
Stikalo za nadzor temperature
Temperaturna varovalka
Temperaturni senzor
Kabel senzorja temperature
Sonda senzorja temperature
temperaturno stikalo
Toplotni izklop
Termično izklopno stikalo
Termična varovalka
toplotna zaščita
Termično stikalo
Senzor termistorja
Nedavne objave
manufacturer of armored thermocouples sensor
Armored thermocouples sensor are the same as industrial assembled thermocouples. As a temperature sensor, it is usually used in conjunction with display instruments, recording instruments and electronic regulators. At the same time, it can also be used as a temperature sensing element for assembled thermocouples.
Kategorija: Temperaturni senzor
Oznake: oklepni senzor termočlenov, Temperaturni senzor
What is an armored thermocouple sensors?
Armoured thermocouples are used as temperature measurement sensors and are usually used in conjunction with temperature transmitters, regulators and display instruments to form a process control system. It is used to directly measure or control the temperature of fluid, steam, gas medium and solid surface in the range of 0-1800℃ in various production processes. Armored thermocouples sensors have many advantages such as flexibility, high pressure resistance, fast thermal response time, sturdiness and durability. It is the same as an industrial assembled thermocouple, and is usually used in conjunction with display instruments, recording instruments and electronic regulators.
Thermocouples sensor used internationally have a standard specification. It is stipulated that the thermocouple is divided into eight different graduations, namely B, R, S, K, N, E, J and T. The lowest temperature can be measured at minus 270℃, and the highest temperature can reach 1800℃. Among them, B, R and S belong to the platinum series of thermocouples sensor. Because platinum is a precious metal, they are also called precious metal thermocouples. The remaining few are called cheap metal thermocouples. There are two types of thermocouple structures, common type and armored type. Ordinary thermocouples are generally composed of hot electrodes, insulating tubes, protective sleeves and junction boxes. While the sheathed thermocouple is: a thermocouple wire, the protective insulating material and the metal rear sleeve assembly combination of the three, the processing of a stretched solid combination. However, the electrical signal of the thermocouple needs a special wire to transmit, and this wire is called a compensation wire. Different thermocouples require different compensating wires, and their main function is to connect with the thermocouple to keep the reference end of the thermocouple away from the power supply, so that the temperature of the reference end is stable. Compensation wires are divided into two types: compensation type and extension type. The chemical composition of the extension wire is the same as that of the thermocouple to be compensated, but in practice, the extension wire is not made of the same material as the thermocouple. Generally, it is replaced by a wire with the same electron density as the thermocouple sensor. The connection between the compensation wire and the thermocouple is generally very clear. The positive connection compensation wire of the thermocouple is a red wire, and the negative connection is connected to the remaining color wire. Most of the general compensation wires are made of copper-nickel alloy.
Armored thermocouples sensor are the same as industrial assembled thermocouples. As a temperature sensor, it is usually used in conjunction with display instruments, recording instruments and electronic regulators. At the same time, it can also be used as a temperature sensing element for assembled thermocouples. It can directly measure the temperature of liquid, steam and its gaseous medium and solid surface in the range of 0℃~800℃ in various production processes. Compared with fabricated thermocouples, armored thermocouples have the advantages of flexibility, high pressure resistance, short thermal response time, sturdiness and durability.
Because the materials of armored thermocouples are generally more expensive (especially when precious metals are used), the distance between the temperature measurement point and the meter is very long. In order to save armored thermocouple materials and reduce costs, compensation wires are usually used to extend the cold end (free end) of the armored thermocouple into the control room where the temperature is relatively stable, and connect it to the terminal of the instrument. It must be pointed out that the function of the thermocouple compensation wire is only to extend the thermoelectrode and move the cold end of the armored thermocouple to the instrument terminal of the control room. It cannot eliminate the influence of the temperature change of the cold junction on the temperature measurement by itself, and cannot compensate. Therefore, other correction methods are needed to compensate for the influence of the cold junction temperature t0≠0°C on the temperature measurement. When using the armored thermocouple compensation wire, you must pay attention to the matching of the models and the polarity can not be connected incorrectly. The temperature of the connecting end of the compensation wire and the armored thermocouple cannot exceed 100°C.
Kontaktirajte nas
Čakam na vašo e-pošto, vam bomo odgovorili v roku 12 ure z dragocenimi informacijami, ki jih potrebujete.
PORODNI IZDELKI
DALLAS Ds18b20 Temperature Sensor Probe
Ultra-small size, ultra-low hardware overhead, strong anti-interference ability, high precision, and strong additional functions make DS18B20 more popular. The advantages of DS18B20 are our best choice for learning microcontroller technology and developing temperature-related small products. Understanding the working principles and applications can broaden your ideas for microcontroller development.
PT100 RTD sensor Probe & Kabli
PT100 thermal resistance acquisition modules can be connected to the RS-485 local control network through the isolated 485 communication interface. RS-485 allows up to 32 PT100 thermal resistance acquisition modules to be hung on the same bus. However, if Link-Max's RS-485 repeater is used, up to 256 PT100 thermal resistance acquisition modules can be connected to the same network, and the maximum communication distance is 1200m.