Kategorije izdelkov
- toplotna varovalka 32
- površinsko nameščene varovalke 12
- termistor 17
- Nosilec varovalk za PCB 27
- Kabelski snop 4
- Držala rezilnih varovalk 17
- termostat 46
- Električna varovalka 14
- Termični odklopnik 20
- Nosilec škatle z varovalkami 36
- Temperaturni senzor 58
- Termično stikalo 64
- Avtomobilska varovalka 19
- Pritrjene varovalke 7
Oznake izdelkov
oklepni senzor termočlenov
Nosilec rezilne varovalke
Avtomobilska varovalka
Avtomobilska varovalka
Keramična cevna varovalka
Odklopnik
Disk termostati
Ds18b20 temperaturni senzor
električna varovalka
Hitro/počasna varovalka
Nosilec škatle z varovalkami
Varovalka iz steklene cevi
Inline držalo za varovalke
Termostat Limit Snap Disc
Mini odklopniki
Zaščita pred preobremenitvijo motorja
Termična zaščita motorja
NTC senzor
NTC termistorski senzor
Nosilec varovalk za PCB
Ponastavljiva varovalka PPTC
PT100 Temperaturni senzor
PTC termistor
priključni snop senzorja
Senzorske sonde & Kabli
enostopenjski kapilarni termostat
Počasna mikro varovalka
Pametni termostat
Varovalke za površinsko montažo
Temp. izklopna povezava
Stikalo za nadzor temperature
Temperaturna varovalka
Temperaturni senzor
Kabel senzorja temperature
Sonda senzorja temperature
temperaturno stikalo
Toplotni izklop
Termično izklopno stikalo
Termična varovalka
toplotna zaščita
Termično stikalo
Senzor termistorja
Nedavne objave
Precision thermocouple supplier
The original factory-manufactured E, J, T thermocouple Sensor is used for the following temperature detection: thermometer, grelnik vode, fireplace, furnace, circuit, rtd, cold junction, pečica, multimeter, digital, industrijski.
The working principle of E, J, T thermocouple Sensor :
When there are two different conductors or semiconductors A and B forming a loop, the two ends of which are connected to each other, as long as the temperatures at the two junctions are different. The temperature at one end is T, called the working end or hot end, and the temperature at the other end is T0, called the free end (also called the reference end) or cold end. An electromotive force will be generated in the loop. The direction and magnitude of the electromotive force are related to the material of the conductor and the temperature of the two junctions. This phenomenon is called “thermoelectric effect”, and the loop composed of two conductors is called “thermocouple”. These two conductors are called “thermoelectrodes”, and the electromotive force generated is called “thermoelectromotive force”.
The thermoelectromotive force consists of two parts of electromotive force, one part is the contact electromotive force of two conductors, and the other part is the thermoelectromotive force of a single conductor.
The size of the thermoelectromotive force in the E, J, T thermocouple Sensor loop is only related to the temperature of the conductor material and the two junctions that make up the thermocouple, and has nothing to do with the shape and size of the thermocouple Sensor. When the two electrode materials of the thermocouple Sensor are fixed, the thermoelectromotive force is the difference of the function of the two junction temperature t and t0.
which is:
This relationship has been widely used in actual temperature measurement. Because the cold junction t0 is constant, the thermoelectromotive force generated by the E, J, T thermocouple only changes with the temperature of the hot junction (measurement end), that is, a certain thermoelectromotive force corresponds to a certain temperature. We can achieve the purpose of temperature measurement as long as we use the method of measuring thermoelectromotive force.
The basic principle of thermocouple temperature measurement is that two conductors of different components form a closed loop. When there is a temperature gradient at both ends, there will be current passing through the loop. At this time, there is an electromotive force-thermoelectromotive force between the two ends, which is the so-called Seebeck effect. Two homogeneous conductors with different components are thermoelectrodes, the end with a higher temperature is the working end, the end with a lower temperature is the free end, and the free end is usually at a certain constant temperature. According to the functional relationship between thermoelectromotive force and temperature, a thermocouple index table is made;
The index table is obtained when the free end temperature is at 0℃, and different thermocouples Sensor have different index tables.
When the third metal material is connected in the thermocouple circuit, as long as the temperature of the two junctions of the material is the same, the thermoelectric potential generated by the thermocouple will remain unchanged. That is, it is not affected by the access of the third metal in the loop. Therefore, when the thermocouple measures the temperature, the measuring instrument can be connected, and the temperature of the measured medium can be known after the thermoelectromotive force is measured. When the thermocouple measures the temperature, the temperature of its cold junction (the measuring end is the hot end, and the end connected to the measurement circuit through the lead is called the cold junction) is required to maintain the same temperature. Its thermoelectric potential is proportional to the measured temperature. If the (environment) temperature of the cold junction changes during measurement, it will seriously affect the accuracy of the measurement. Take certain measures to compensate at the cold junction, and the influence caused by the temperature change of the cold junction is called the cold junction compensation of the thermocouple is normal. Dedicated compensation wire for connection with measuring instrument.
Calculation method of thermocouple Sensor cold junction compensation:
From millivolt to temperature: Measure the cold junction temperature, convert it to the corresponding millivolt value, add it to the millivolt value of the thermocouple, and calculate the temperature;
From temperature to millivolt: Measure the actual temperature of the cold end temperature, oz, in terms of millivolts, after subtracting the values derived mV, to obtain the temperature.
The original factory-manufactured E, J, T thermocouple Sensor is used for the following temperature detection: thermometer, grelnik vode, fireplace, furnace, circuit, rtd, cold junction, pečica, multimeter, digital, industrijski.
Kontaktirajte nas
Čakam na vašo e-pošto, vam bomo odgovorili v roku 12 ure z dragocenimi informacijami, ki jih potrebujete.
PORODNI IZDELKI
China Custom Thermistor sensor Probe Assembly for temperature control
High-End Resistor sensor Probe Manufacturer — YAXUN specializes in thermistor featuring temperature sensitivity and AEC-Q200 qualified. TCTR - NTC Thick Film Thermistor. 47-1.6MΩ. Tightest tolerance 1%. B Value 2410K - 4800K.
Thermistor Temp Sensor — Silicon-Based Linear Thermistors At The Same Cost And Size Of Traditional NTC Thermistors. Achieve High Accuracy System Reliability With The Industry's Smallest Linear Thermistors.
manufacturer of armored thermocouples sensor
Armored thermocouples sensor are the same as industrial assembled thermocouples. As a temperature sensor, it is usually used in conjunction with display instruments, recording instruments and electronic regulators. At the same time, it can also be used as a temperature sensing element for assembled thermocouples.
PT100 RTD sensor Probe & Kabli
PT100 thermal resistance acquisition modules can be connected to the RS-485 local control network through the isolated 485 communication interface. RS-485 allows up to 32 PT100 thermal resistance acquisition modules to be hung on the same bus. However, if Link-Max's RS-485 repeater is used, up to 256 PT100 thermal resistance acquisition modules can be connected to the same network, and the maximum communication distance is 1200m.
thermistor sensor probes and components
termistor (negativni temperaturni koeficient) sensor probes (OVERMOLDED PROBE, closed end SST tube; Silicone Foley Catheter; epoxy sealed, Nickel plated brass tube) /components (Cable & connector) suitable for various applications and industries. Our THERMISTOR probes and components are suitable for temperature sensing applications such as surface temperature detection, air-gas, electrical appliances, power supplies, HVAC/refrigeration systems, liquids, medical treatment, and monitoring.
What is thermocouple sensor?
The appearance of various thermocouple sensor probes is often very different due to needs. However, their basic structures are roughly the same, usually composed of main parts such as a thermode, an insulating sleeve protection tube, and a junction box, and are usually used in conjunction with display instruments, recording instruments and electronic regulators.