produktkategori
Produkttaggar
bepansrade termoelement sensor
blad Säkringshållare
Säkring för bilblad
Bilsäkring
Keramisk rörsäkring
Strömbrytare
Skivtermostater
Ds18b20 temperatursensor
elektrisk säkring
Snabb/långsam säkring
Säkringsboxhållare
Glasrörssäkring
Inline säkringshållare
Limit Snap Disc-termostat
Mini effektbrytare
Motor överbelastningsskydd
Termiskt motorskydd
NTC-sensor
NTC termistorsensor
PCB-monterad säkringshållare
PPTC återställbar säkring
PT100 Temperaturgivare
PTC termistor
sensorkontaktnät
Sensorsonder & Kablar
enstegs kapillärtermostat
Slow Blow Micro Fuse
Smart termostat
Ytmonterade säkringar
Temp Cutoff Link
Temperaturkontrollbrytare
Temperatursäkring
Temperatursensor
Temperaturgivare kabel
Temperatursensorsond
temp switch
Termisk avstängning
Termisk brytare
Termisk säkring
termiskt skydd
Termobrytare
Termistorsensorsond
Senaste inlägg
Anpassad snabb snabb/långsam keramiskt rörsäkringsström
beställnings- 5 * 20mm 6x30mm,6x25 mm, 3.6x10 mm, 10x38mm keramiska rörsäkringar Snabb/ Långsam säkring Med ledningar och ledningar 250V 0,5A 1A 1,5A 2A 2,5A 3A 4A 5A 6,3A 10A 12A 15A 20A 25A 30A online idag!
Kategori: Elektrisk säkring
Taggar: Keramisk rörsäkring, elektrisk säkring, Glasrörssäkring, Slow Blow Micro Fuse
beställnings- 5 * 20mm 6x30mm,6x25 mm, 3.6x10 mm, 10x38mm keramiska rörsäkringar Snabb/ Långsam säkring Med ledningar och ledningar 250V 0,5A 1A 1,5A 2A 2,5A 3A 4A 5A 6,3A 10A 12A 15A 20A 25A 30A online idag!
Ceramic Tube Fuses define it as a “fuse link” in international standards. It is an electrical component installed in a circuit to ensure the safe operation of the circuit. Electronic products are all-encompassing, and these products that require electricity must be equipped with the same small components and fuses that are responsible for safety. Not only are there fuses on 3C products, fuses must also be installed on ordinary cars or electric cars.
Now as the products become smaller and smaller, they are more and more integrated, and the shape and size of fuses are also very different from traditional fuses. Till exempel, the Ceramic Tube fuse of the mobile phone must conform to the trend of fast charging. To withstand the instantaneous large current, to achieve its protective function, the requirements of fuses are getting higher and higher.
The glass tube fuses we usually see are not a single material. It is an alloy made of lead, antimony, and tin. This is to achieve the purpose of low melting point and these metals are added, copper caps at both ends, so that the conductivity will be better, the surface of the copper cap is nickel plated.
The shape of the Ceramic Tube fuse has the earliest strip-shaped fuse, which is directly fixed with screws at both ends, and is used on old-style electric brakes.
The chip Ceramic Tube fuse is composed of a plastic sheet and two metal sheets, which are commonly used in automobiles, and glass tubes are often used in electronic products.
Cylindrical fuses will directly solder the pins at both ends to the circuit board. The square fuse has the characteristics of insulation and space saving, and is often used in electronic products such as computers.
The function of the fuse is that when the circuit malfunctions or is abnormal, the current increases continuously, and the increased current may damage the components, burn the circuit or even cause a fire.
If Ceramic Tube fuse is installed in the circuit, when the current abnormally rises to a certain level, the Ceramic Tube fuse is blown to cut off the current and protect the appliance.
Fuses were born in the 1880s. Edison invented Ceramic Tube fuse equivalent to a safety valve in the circuit and applied for a patent. The Ceramic Tube fuse was invented at the time to protect incandescent lamps, because incandescent lamps were very expensive at the time when they were first invented.
With the development of society and the continuous increase of electrical appliances, the Ceramic Tube fuse industry has also developed rapidly. The fuse industry in China started relatively late, and it was not until the 1970s that TV sets were localized that they promoted the development of fuses in China.
The working principle of Ceramic Tube fuse is that when a current passes through a conductor, the conductor will generate heat due to the resistance of the conductor. After the material and shape of the fuse are determined, its resistance is fixed. When current flows through it, it will heat up, and its heat generation will increase with time. The size of the current and resistance determines the rate of heat generation. The structure of the Ceramic Tube fuse and its installation condition determine the rate of heat consumption. If the rate of heat generation is less than the rate of heat dissipation, the fuse will not blow.
If the rate of heat generation is equal to the rate of heat dissipation, it will not melt for a long time. If the rate of heat generation is greater than the rate at which heat disappears, the amount of heat generated will increase and the increase in heat will cause the temperature to rise. When the temperature rises above the fuse’s melting point, the fuse will blow.
Manufacture of common glass tube fuses. The silicon dioxide material is first drawn into a transparent glass tube with a diameter of 5 mm through high temperature, and then cut into a length of 20 mm. The two ends of the glass tube must be rounded with high temperature to avoid the sharp edges of the glass tube from scratching the fuse when passing through the fuse.
An alloy fuse is placed in the glass tube, and the printed top and bottom covers are welded together with the Ceramic Tube fuse by high frequency.
Finally, the machine automatically detects the Ceramic Tube fuse, pops out the unqualified fuse, and packs the qualified fuse.
Some people may wonder why the common Ceramic Tube fuse is installed in a glass tube. First, the glass tube is insulated and difficult to ignite, ensuring that the fuse is the only conductive connection intermediary at both ends. The cheap price of glass tube is also the reason to use it. Dessutom, the glass tube can see whether the internal fuse is blown, it is relatively easy to judge the quality of the fuse, and the glass tube is not vacuum.
Med teknikens utveckling, more types of fuses have appeared. Such as the resettable fuse, this type of fuse is automatically deformed when the temperature exceeds a certain safe temperature, leading to power failure. After the temperature is restored, it can be automatically powered on to work normally without manual intervention.
Product Details
Intentions to develop, to use technology to benefit society
Brytkapacitet | Material | Driftstemperatur | Lödningsförhållanden |
1500A at 250V AC(1A-10A) | Fuse body –ceramic tube Ändlock–nickelpläterad mässing Hårpiska–tennpläterad koppar på nickelpläterad mässingslock |
-40℃~+125℃ | Våglödning:260℃,≤5S Handlödning: 360℃,≤1S |
Funktionella egenskaper
Testar ström | Blåstid | |
Min | Max | |
150% | 1 timme | – |
210% | 1 S | 30min |
275% | 750ms | 80s |
400% | 95ms(1A-3.15A) 150ms(4A-16A) |
5S(1A-10A) 8S(12.5A-16A) |
1000% | 10 ms | 150ms |
Godkännanden(○ Väntande ● Godkännanden)
Aktuellt betyg | Spänningsvärde | Norminal Melting I2T(A2sek) | Godkännanden | |||||
VDE | CCC | CQC | UL | PSE | KC | |||
1A | 250V | 1.4 | ● | ● | ● | ● | ||
1.25A | 250V | 2.0 | ● | ● | ● | ● | ● | |
1.6A | 250V | 3.3 | ● | ● | ● | ● | ● | |
2A | 250V | 5.2 | ● | ● | ● | ● | ● | |
2.5A | 250V | 8.3 | ● | ● | ● | ● | ● | |
3.15A | 250V | 13 | ● | ● | ● | ● | ● | |
4A | 250V | 22 | ● | ● | ● | ● | ● | |
5A | 250V | 36 | ● | ● | ● | ● | ● | |
6.3A | 250V | 54 | ● | ● | ● | ● | ● | |
8A | 250V | 90 | ● | ● | ● | ● | ● | |
10A | 250V | 130 | ● | ● | ● | ● | ● | |
12A | 250V | 112 | ○ | ● | ||||
12.5A | 250V | 216 | ○ | ○ | ○ | ● | ○ | |
15A | 250V | 252 | ○ | ● | ||||
16A | 250V | 332 | ○ | ○ | ○ | ○ |
Kontakta oss
Väntar på ditt mejl, vi kommer att svara dig inom 12 timmar med värdefull information du behövde.
RELATERADE PRODUKTER
RS PRO 5x20 mm patron Snabb~långsamt urbrutna säkringar med bly
Miniature 5x20mm Medium-Acting Glass Body Fuse
VAC (V): 250
Nominell smältning I2T (A2sek): 0.005, 0.009, 0.011, 0.017, 0.031, 0.057, 0.085, 0.12, 0.13, 0.16 more
Resistance (Åh): 0.01167, 0.01578, 0.03045, 0.04515, 0.0551
Vilka är de olika storlekarna på glassäkringar?
MEN, SFE 4. (1/4" x 5/8")
SFE 6. (1/4" x 3/4")
AGW, SFE 7.5, SFE 9. (1/4" x 7/8")
AGX. (1/4" x 1")
SFE 14. (1/4" x 1-1/16")
AGC, SFE 20, Storbritannien. (1/4" x 1-1/4")
HJÄRNA, SFE 30. (1/4" x 1-7/16")
AGU. (13/32" x 1-1/2")