produktkategori
Produkttaggar
bepansrade termoelement sensor
blad Säkringshållare
Säkring för bilblad
Bilsäkring
Keramisk rörsäkring
Strömbrytare
Skivtermostater
Ds18b20 temperatursensor
elektrisk säkring
Snabb/långsam säkring
Säkringsboxhållare
Glasrörssäkring
Inline säkringshållare
Limit Snap Disc-termostat
Mini effektbrytare
Motor överbelastningsskydd
Termiskt motorskydd
NTC-sensor
NTC termistorsensor
PCB-monterad säkringshållare
PPTC återställbar säkring
PT100 Temperaturgivare
PTC termistor
sensorkontaktnät
Sensorsonder & Kablar
enstegs kapillärtermostat
Slow Blow Micro Fuse
Smart termostat
Ytmonterade säkringar
Temp Cutoff Link
Temperaturkontrollbrytare
Temperatursäkring
Temperatursensor
Temperaturgivare kabel
Temperatursensorsond
temp switch
Termisk avstängning
Termisk brytare
Termisk säkring
termiskt skydd
Termobrytare
Termistorsensorsond
Senaste inlägg
Metal Thermal Fuse for Limit Temperature Protection
Metal thermal fuse link (thermal cut off ) consists of a sliding contact, a spring, and an electrically nonconductive thermal pellet. Before the limit thermal fuse is activated, current flows from the left lead to the sliding contact and through the metal housing to the right lead. Metal Shell Thermal Fuse Cutoff 250VAC 10A Temperature Fuse link TF 72-250℃ (192℃).
Kategori: Termisk säkring
Taggar: Temp Cutoff Link, Temperatursäkring, Termisk avstängning, Termisk säkring
Metal thermal fuse link (thermal cut off ) consists of a sliding contact, a spring, and an electrically nonconductive thermal pellet. Before the limit thermal fuse is activated, current flows from the left lead to the sliding contact and through the metal housing to the right lead. When the external temperature reaches a predetermined temperature, the organic matter meltsand the compression spring becomes loose. That is, the spring expands and the sliding contact is separated from the left lead. The circuit is opened and the current between the sliding contact and the left lead is cut off.
The metal shell temperature fuse link includes a metal pin, a sealing resin, a shell, a thermal fuse, and two fusible alloys. The metal pin and the two ends of the two fusible alloys are welded and connected. The fusible alloy and part of the metal pin are encapsulated in the insulating space of the shell by the sealing resin, and the thermal fuse is filled in the internal confined space encapsulated by the shell and the sealing resin. The two fusible alloys are welded and connected with the metal pin in an “X” shape, and there is a triangle protruding inward at the bottom of the shell. During the operation of the utility model, the intersection of the two fusible alloys is weak, and the disconnection point starts from the intersection. The metal pin has a relatively large adsorption on the fusible alloy, which is conducive to the contraction of the fusible alloy to the pin, avoiding the situation where the fusible alloy is reconnected. The structure of the shell can reduce the generation of arcs. Avoid sparks and burning safety hazards, improve safety of use, and after disconnection, the shell can also effectively prevent the melted fusible alloy from connecting again, permanently disconnecting the circuit.
1. A novel thermal fuse, comprising a metal pin (1), a sealing resin
(2), a shell
(3), a flux
(4), and two fusible alloys
(5), wherein the metal pin and the two fusible alloys are welded at both ends, the fusible alloys and part of the metal pin are encapsulated in the insulating space of the shell by the sealing resin, and the flux is filled in the internal sealed space encapsulated by the shell and the sealing resin. The invention is characterized in that the two fusible alloys are welded and connected to the metal pin in an “X” shape, and the bottom of the shell has a triangle shape protruding inward.
Our Metal thermal fuses are perfect for when you need an accurate and reliable solution for upper-limit temperature protection.
With our reliable protective thermal fuses, the active trigger mechanism is an exclusively formulated, electrically nonconductive pellet. When a predetermined temperature is reached that pellet melts, allowing the compression spring to relax. The trip spring then slides the contact away from the lead and the circuit is opened.
Widely used in:Transformatorer, Electric motors, Electric fans, Hair dryers, Electric irons, Rice cookers, Copiers, Electric stoves, Chargers, power taps, Water dispensers, Coffee makers etc.
Kontakta oss
Väntar på ditt mejl, vi kommer att svara dig inom 12 timmar med värdefull information du behövde.
RELATERADE PRODUKTER
250v 2a /10a Termisk skuren länk för bordsfläkt/mixer
Termisk säkring kan känna av överhettning som genereras av onormal drift av elektriska och elektroniska produkter, därigenom bryta kretsen för att undvika brand. Används vanligtvis i: hårtorkar, elektriska strykjärn, riskokare, elektriska spisar, transformatorer, motorer, vattenautomater, kaffekannor, etc. Termosäkringen kan inte användas igen efter drift, och fungerar endast en gång vid smälttemperaturen.
Mekaniskt motstånd termiska avstängningar Enheter (DF SF Series 10amp)
Senare, spänningen mellan kontakterna på den termiska avstängningen och DC-kretsen stiger för att säkerställa att DC-kretsen kopplas bort. Genom föreliggande uppfinning, problemet att den termiska avstängningen i DC-kretsen inte effektivt kan bryta kretsen är löst, och effekten av att förbättra kretssäkerheten uppnås.