ürün kategorileri
Ürün Etiketleri
Çin Özel Hidrolik, Tek Manyetik Deniz Devre Kesicileri
Denizcilik devre kesicileri BD serisi – hidrolik elektromanyetik devre kesici; BC serisi – küçük hidrolik devre kesici; BC-1 kutuplu hidrolik manyetik devre kesici; BA serisi – hidrolik devre kesici; tek manyetik devre kesici.
Marine circuit breakers, reliable operation at -55℃~125℃, rail installation. AC/DC 1-600A-cable device protects marine circuit breakers. 1-100A can be customized, universal for AC/DC; multiple control modes, carrying 100% anma akımı. Marine circuit breakers are used to resist the excitation surge current when the transformer is first powered on. Aralarında, the short-circuit protection of the circuit breaker is delayed, yani, adjustable delay S parameter short-circuit protection; the series-connected fuse is used to perform transient short-circuit protection. The two are matched to complete short-circuit instantaneous protection and short-circuit short-delay protection.
Product selection:
BD series – hidrolik elektromanyetik devre kesici; BC serisi – küçük hidrolik devre kesici; BC-1 kutuplu hidrolik manyetik devre kesici; BA serisi – hidrolik devre kesici; tek manyetik devre kesici.
Purchase reliable marine circuit breakers for your boating needs. Safety rated and waterproof boat circuit breakers with single lever
Marine overload protection devices meet the following requirements:
Allow normal currents (less than or equal to the rated current of the system or equipment) to flow continuously.
Allow temporary overload conditions, such as those associated with motor starting or capacitor switching, without unnecessary tripping.
Capable of detecting and tripping circuit breakers under overload conditions that, due to the magnitude and duration of their current, can damage equipment insulation or the equipment itself.
When equipment insulation fails, short-circuit currents of the circuit breaker rating may flow many times over. To reduce thermal and dynamic stresses that may occur to system components or equipment, the short circuit should be interrupted as quickly as possible. The rated current of the circuit breaker is the rated current that appears on the front of the product. The generation of the tripping characteristic or time delay curve is based on a percentage of this value.
HAYIR. Model Spesifikasyonu: RSB1-50
1 Company Code Name: RS
2 Product Code: B Hydraulic magnetic circuit breaker
3 Design Serial Number:1
4 Maximum Current: 50
5 Tripping curve: A2 AC Delay Medium
6 Nominal Akım: 15A
7 Kutup: 1P
8 Mounting Method: L Screw mounting
9 Connection Mode: H Quick plug wiring
10 Handle Type: C1 Black long handle white legend ON/ I OFF/O
11 Number of actuators: M One per pole
12 Accessory code: 0 No accessory
2、Teknik Parametreler
2.1 Değerlendirilmiş Akım, rated voltage and rated breaking
3、Yalıtım Direnci: At 500VDC, the minimum is 100M
Ah (cold state)
4、Power-Frequency Withstand Voltage: 50/60Hz 1500V 60s
5、Working Environment:Çalışma sıcaklığı:-40℃~+85℃ Altitude:≤2000m RH of the Atmosphere:≤95% In the environment where there is no explosion, no corrosion of metals and destruction of insulating gases and conductive dust, where there’s no rain or snow Impact on electrical performance when altitude equal or above 4000m
Tripping characteristic: Action time slightly extended but still meet the standard requirements;
Withstand Voltage: No effect;
Temperature rise: No effect;
Kırılma kapasitesi : Derating to 80%
6、Protection system: Electromagnetic hydraulic release / free tripping structure
7、Hayat: Mechanical life 10000times, under rate voltage and current, electrical life 6000times
Bize Ulaşın
E-postanızı bekliyorum, size içinde cevap vereceğiz 12 ihtiyaç duyduğunuz değerli bilgilerle saatler.