RTD PT100 带电缆温度传感器探头

什么是铂热电阻传感器?
RTD (电阻温度检测器) 是铂热电阻,其阻值随温度变化而变化. 它的电阻随着传感器温度的升高而增加. 电阻和温度之间的关系是众所周知的,并且随着时间的推移可重复. RTD 是无源器件. 它本身不产生输出. 外部电子器件可通过使小电流流过传感器产生电压来测量传感器电阻. 通常 1 mA以下测量电流, 最大限度 5 嘛, 无自热风险.

A Platinum thermal resistance Temperature Detector (PT100 RTD) is a sensor used to measure temperature by changing resistance proportionally to temperature. The RTD PT100 is designed with a basic temperature element and a complete probe and wiring harness assembly. These so-called RTD probes consist of an Platinum thermal resistance element, a sheath or housing, epoxy or filler material, extension leads, and sometimes a connector or termination. Different sensor materials can be used based on customer requirements for material compatibility, accuracy and measurement range. Standard kits and custom designs provide the flexibility to design the most suitable RTD temperature sensor for many different applications.
RTD PT100 temperature sensors and probes can be integrated into a variety of applications across a variety of industries. These temperature sensors are certified by multiple agencies to operate on board-mounted pressure components; they can also operate in harsh and hazardous environments. Our broad range of temperature sensor product options address the specific sensing needs of demanding OEM applications including medical, aerospace, 汽车, instrumentation, 家电, motor control and HVAC and refrigeration systems.

RTD PT100 standard tolerances
RTDs are built to several standardized curves and tolerances. The most commonly used normalized curve is theDINcurve. This curve describes the resistance versus temperature characteristics of platinum with a 100 ohm sensor, standardized tolerances, and measurable temperature range.
The DIN standard specifies a base resistance of 100 ohms at 0°C and a temperature coefficient of 0.00385 ohms/ohms/°c. The nominal output of DIN RTD sensors is as follows:
DIN RTD has three standard tolerance classes. These tolerances are defined as follows:
DIN Class A: ±(0.15 + 0.002 |时间|℃)
DIN Class B: ±(0.3 + 0.005 |时间|℃)
DIN Class C: ±(1.2 + 0.005 |时间|℃)

0°C/ ohms
0: 100.00
10: 103.90
20: 107.79
30: 111.67
40: 115.54
50: 119.40
60: 123.24
70: 127.07
80: 130.89
90: 134.70
100: 138.50

RTD component type
When determining the type of RTD element, first consider the instrument used to read the sensor. Select a component type that is compatible with the instrument’s sensor input. By far the most commonly used RTD is 100 ohm platinum with a temperature coefficient of 0.00385.
Component Type Base Resistor (ohms) TCR (ohms/ohms/°C)
Platinum 100 ohms at 0°C .00385
Platinum 100 ohms at 0°C .00392
Platinum 100 ohms at 0°C .00375
Nickel 120 ohms at 0°C .00672
铜 10 ohms at 25°C .00427

RTD accuracy

Second, determine the required measurement accuracy. Accuracy is a combination of the base resistor tolerance (resistance tolerance at calibration temperature) and the resistor tolerance temperature coefficient (characteristic slope tolerance). Any temperature above or below this will have a wider tolerance band or less accuracy (see figure below). The most commonly used calibration temperature is 0°C.

The RTD PT100 sensor is available in several different lead configurations. The most common configuration is the single-element three-lead configuration. A schematic of the available lead configurations is shown below:

PT100/PT1000 two-wire sensors are typically used in applications where accuracy is not important. A two-wire configuration enables the simplest measurement technique, but has inherent inaccuracies due to the resistance of the sensor leads. In a two-wire configuration, it is not possible to directly compensate for the lead resistance that causes increased offset in the resistance measurement.

The PT100/PT1000 three-wire sensor has a compensation loop that can eliminate lead resistance during measurement. With this configuration, the controller/measuring device can take two measurements. For the first measurement, measure the total resistance of the sensor and connecting leads. During the second measurement, measure the resistance of the compensation loop resistor. The actual net resistance is determined by subtracting the compensation loop resistance from the total resistance. Three-wire sensors are the most common configuration and offer a good combination of accuracy and convenience.

PT100温度传感器

PT100温度传感器

PT100传感器探头

PT100传感器探头

RTD Resistance versus Temperature

RTD Resistance versus Temperature

Platinum RTD Standard Accuracy

Platinum RTD Standard Accuracy

PT100/PT1000 four-wire sensor configuration and measurement technology measures sensor resistance without being affected by the leads. While this technique is more accurate, many industrial controllers/measurement devices are unable to achieve true four-wire measurements.

The transition from sensor leads to field wiring is usually done at the connector that connects to the sensor. Terminal blocks are provided for easy connection.

Measuring temperature with a resistance temperature detector is actually measuring resistance. An unbalanced Wheatstone bridge is often used to measure resistance. When measuring the resistance of a sensing element, all external factors must be minimized or compensated for in order to obtain an accurate reading.

One major cause of errors can be the resistance of the leads, especially in a two-lead configuration.

The resistor is in series with the sensing element, so the reading is the sum of the sensing element and lead resistance. Two-lead RTDs can be used when the resistance of the sensing element is high and the resistance of the leads is low.

然而, when the resistance of the leads is relatively high, it must be compensated. Compensation is available in a three-lead configuration. As shown in the three-lead diagram, one side of the power supply is connected to one side of the RTD through L3. This puts L1 and L2 on opposite sides of the bridge, so they cancel each other out and have no effect on the bridge output voltage.
It is recommended to use a three-lead connection for RTDs, especially if the sensing element resistance is low, where a small lead resistance can have a large impact on the accuracy of the reading.

联系我们

等待您的电子邮件, 我们将在短时间内回复您 12 小时提供您需要的有价值的信息.

相关产品

请求报价

填写我们的报价请求表,我们将尽快回复您的消息!